| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An integer overflow vulnerability exists in the function multiTransfer of Rocket Coin (XRC), an Ethereum token smart contract. An attacker could use it to set any user's balance. |
| An issue was discovered in cmft through 2017-09-24. The cmft::rwReadFile function in image.cpp allows remote attackers to cause a denial of service (stack-based buffer overflow and application crash) or possibly have unspecified other impact. |
| Multiple Persistent cross-site scripting (XSS) issues in the Techotronic all-in-one-favicon (aka All In One Favicon) plugin 4.6 for WordPress allow remote attackers to inject arbitrary web script or HTML via Apple-Text, GIF-Text, ICO-Text, PNG-Text, or JPG-Text. |
| An XML external entity vulnerability in the XOG functionality, in CA PPM 14.3 and below, 14.4, 15.1, 15.2 CP5 and below, and 15.3 CP2 and below, allows remote attackers to conduct server side request forgery attacks. |
| Insufficient input validation in the gridExcelExport functionality, in CA PPM 14.3 and below, 14.4, 15.1, 15.2 CP5 and below, and 15.3 CP2 and below, allows remote attackers to execute reflected cross-site scripting attacks. |
| Insufficient input sanitization of two parameters in CA PPM 14.3 and below, 14.4, 15.1, 15.2 CP5 and below, and 15.3 CP2 and below, allows remote attackers to execute SQL injection attacks. |
| An XML external entity vulnerability in the XOG functionality, in CA PPM 14.3 and below, 14.4, 15.1, 15.2 CP5 and below, and 15.3 CP2 and below, allows remote attackers to access sensitive information. |
| Unprotected storage of credentials in CA PPM 14.3 and below, 14.4, 15.1, 15.2 CP5 and below, and 15.3 CP2 and below, allows attackers to access sensitive information. |
| A lack of authentication, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows remote attackers to conduct a variety of attacks, including file reading/writing. |
| A hardcoded passphrase, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information. |
| A hardcoded secret key, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information. |
| Twig before 2.4.4 allows Server-Side Template Injection (SSTI) via the search search_key parameter. NOTE: the vendor points out that Twig itself is not a web application and states that it is the responsibility of web applications using Twig to properly wrap input to it |
| A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known. |
| A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known. |
| A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affected CP devices could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. At the time of advisory publication no public exploitation of this vulnerability was known. |
| A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into following a malicious link. User interaction is required for a successful exploitation. At the time of advisory publication no public exploitation of this vulnerability was known. |