Externally controlled reference to a resource in another sphere in quarantine functionality in Synology Antivirus Essential before 1.4.8-2801 allows remote authenticated users to obtain privilege via unspecified vectors.
Search vulnerabilities
SAP NetWeaver ABAP Server and ABAP Platform, versions - 700, 701, 702, 731, 740, 750, 751, 752, 753, 754, 755, 804, does not create information about internal and external RFC user in consistent and distinguished format, which could lead to improper authentication and may be exploited by malicious users to obtain illegitimate access to the system.
SAP Commerce, versions - 1808, 1811, 1905, 2005, 2011, Backoffice application allows certain authorized users to create source rules which are translated to drools rule when published to certain modules within the application. An attacker with this authorization can inject malicious code in the source rules and perform remote code execution enabling them to compromise the confidentiality, integrity and availability of the application.
org/mitre/oauth2/web/OAuthConfirmationController.java in the OpenID Connect server implementation for MITREid Connect through 1.3.3 contains a Mass Assignment (aka Autobinding) vulnerability. This arises due to unsafe usage of the @ModelAttribute annotation during the OAuth authorization flow, in which HTTP request parameters affect an authorizationRequest.
The Blog module in Kentico CMS 5.5 R2 build 5.5.3996 allows SQL injection via the tagname parameter.
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Remote unauthenticated users can execute arbitrary code via crafted UDP packets with no prior authorization or authentication.
An issue was discovered in open-falcon dashboard version 0.2.0, allows remote attackers to gain, modify, and delete sensitive information via crafted POST request to register interface.
EyesOfNetwork 5.3-10 uses an integer of between 8 and 10 digits for the session ID, which might be leveraged for brute-force authentication bypass (such as in CVE-2021-27513 exploitation).
Delta Industrial Automation COMMGR Versions 1.12 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code.
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code.
Mesa Labs AmegaView Command Injection
Mesa Labs AmegaView Versions 3.0 and prior has a command injection vulnerability that can be exploited to execute commands in the web server.
Mesa Labs AmegaView command injection
Mesa Labs AmegaView version 3.0 is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1).
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection.
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
An issue was discovered in the rand_core crate before 0.6.2 for Rust. Because read_u32_into and read_u64_into mishandle certain buffer-length checks, a random number generator may be seeded with too little data.
An issue was discovered in the yottadb crate before 1.2.0 for Rust. For some memory-allocation patterns, ydb_subscript_next_st and ydb_subscript_prev_st have a use-after-free.
An issue was discovered in the nb-connect crate before 1.0.3 for Rust. It may have invalid memory access for certain versions of the standard library because it relies on a direct cast of std::net::SocketAddrV4 and std::net::SocketAddrV6 data structures.