Search vulnerabilities

Results 425,103

CVE-2024-4496

Tenda i21 formWifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2023-1732

Improper random reading in CIRCL

When sampling randomness for a shared secret, the implementation of Kyber and FrodoKEM, did not check whether crypto/rand.Read() returns an error. In rare deployment cases (error thrown by the Read() function), this could lead to a predictable shared secret. The tkn20 and blindrsa components did not check whether enough randomness was returned from the user provided randomness source. Typically the user provides crypto/rand.Reader, which in the vast majority of cases will always return the right number random bytes. In the cases where it does not, or the user provides a source that does not, the blinding for blindrsa is weak and integrity of the plaintext is not ensured in tkn20.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-32076

in-toto vulnerable to Configuration Read From Local Directory

in-toto is a framework to protect supply chain integrity. The in-toto configuration is read from various directories and allows users to configure the behavior of the framework. The files are from directories following the XDG base directory specification. In versions 1.4.0 and prior, among the files read is `.in_totorc` which is a hidden file in the directory in which in-toto is run. If an attacker controls the inputs to a supply chain step, they can mask their activities by also passing in an `.in_totorc` file that includes the necessary exclude patterns and settings. RC files are widely used in other systems and security issues have been discovered in their implementations as well. Maintainers found in their conversations with in-toto adopters that `in_totorc` is not their preferred way to configure in-toto. As none of the options supported in `in_totorc` is unique, and can be set elsewhere using API parameters or CLI arguments, the maintainers decided to drop support for `in_totorc`. in-toto's `user_settings` module has been dropped altogether in commit 3a21d84f40811b7d191fa7bd17265c1f99599afd. Users may also sandbox functionary code as a security measure.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2024-28781

IBM UrbanCode Deploy cross-site scripting

IBM UrbanCode Deploy (UCD) 7.0 through 7.0.5.20, 7.1 through 7.1.2.16, 7.2 through 7.2.3.9, 7.3 through 7.3.2.4, and 8.0 through 8.0.0.1 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 285654.

CVSS 3.1 · 5.4 Medium EPSS < 1% KEV · Not listed
Vendors
Ibm
CVE-2024-4237

Tenda AX1806 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
CVE-2024-4238

Tenda AX1806 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
CVE-2024-4239

Tenda AX1806 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
CVE-2024-4240

Tenda W9 formQosManageDouble_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2024-4241

Tenda W9 formQosManageDouble_auto stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4242

Tenda W9 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4243

Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4244

Tenda W9 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4245

Tenda i21 formQosManageDouble_user stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4246

Tenda i21 formQosManageDouble_auto stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-4497

Tenda i21 formexeCommand stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2024-4247

Tenda i21 formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2024-4252

Tenda i22 formSetUrlFilterRule stack-based overflow

A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2022-40196

Improper access control in the Intel(R) oneAPI DPC++/C++ Compiler before version 2022.2.1 and Intel C++ Compiler Classic before version 2021.7.1 for some Intel(R) oneAPI Toolkits before version 2022.3.1 may allow an authenticated user to potentially enable escalation of privilege via local access.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2022-38136

Uncontrolled search path in the Intel(R) oneAPI DPC++/C++ Compiler for Windows and Intel Fortran Compiler for Windows before version 2022.2.1 for some Intel(R) oneAPI Toolkits before version 2022.3.1 may allow an authenticated user to potentially enable escalation of privilege via local access.

CVSS 3.1 · 6.7 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-0187

hw: Intel: Improper access control in the BIOS firmware may cause escalation privilege

Improper access control in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable an escalation of privilege via local access.

CVSS 3.1 · 3.2 Low EPSS < 1% KEV · Not listed
Vendors