Search vulnerabilities

Results 426,252

CVE-2023-5059

Santesoft Sante FFT Imaging Out-of-bounds Read

Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-39431

Santesoft Sante DICOM Viewer Pro Out-of-bounds Write

Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-35986

Santesoft Sante DICOM Viewer Pro Stack-based Buffer Overflow

Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-38584

Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow

In Weintek's cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.

CVSS 3.1 · 9.8 Critical EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2023-40145

Weintek cMT3000 HMI Web CGI OS Command Injection

In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.

CVSS 3.1 · 8.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2023-43492

Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow

In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2023-42769

Sielco Radio Link and Analog FM Transmitters Improper Access Control

The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors
CVE-2023-45317

Sielco Radio Link and Analog FM Transmitters Cross-Site Request Forgery

The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests. This can be exploited to perform certain actions with administrative privileges if a logged-in user visits a malicious web site.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2023-45228

Sielco Radio Link and Analog FM Transmitters Improper Access Control

The application suffers from improper access control when editing users. A user with read permissions can manipulate users, passwords, and permissions by sending a single HTTP POST request with modified parameters.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2023-0897

Session FIxation in Sielco PolyEco1000

Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2023-5754

Improper Restriction of Excessive Authentication Attempts in Sielco PolyEco1000

Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-46662

Improper Access Control in Sielco PolyEco1000

Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2023-46663

Improper Access Control in Sielco PolyEco1000

Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2023-46664

Improper Access Control in Sielco PolyEco1000

Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2023-46665

Improper Access Control in Sielco PolyEco1000

Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-5777

Weintek EasyBuilder Pro Use of Hard-coded Credentials

Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-5719

Red Lion Crimson Improper Neutralization of Null Byte or NUL Character

The Crimson 3.2 Windows-based configuration tool allows users with administrative access to define new passwords for users and to download the resulting security configuration to a device. If such a password contains the percent (%) character, invalid values will be included, potentially truncating the string if a NUL is encountered. If the simplified password is not detected by the administrator, the device might be left in a vulnerable state as a result of more-easily compromised credentials. Note that passwords entered via the Crimson system web server do not suffer from this vulnerability.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-0898

Uncontrolled Search Path Element in GE MiCOM S1 Agile

General Electric MiCOM S1 Agile is vulnerable to an attacker achieving code execution by placing malicious DLL files in the directory of the application.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Ge
Products