Barco wePresent WiPG-1600W devices allow Authentication Bypass. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W web interface does not use session cookies for tracking authenticated sessions. Instead, the web interface uses a "SEID" token that is appended to the end of URLs in GET requests. Thus the "SEID" would be exposed in web proxy logs and browser history. An attacker that is able to capture the "SEID" and originate requests from the same IP address (via a NAT device or web proxy) would be able to access the user interface of the device without having to know the credentials.
Search vulnerabilities
Barco wePresent WiPG-1600W devices download code without an Integrity Check. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W firmware does not perform verification of digitally signed firmware updates and is susceptible to processing and installing modified/malicious images.
Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.
Prototype pollution vulnerability in 'libnested' versions 0.0.0 through 1.5.0 allows an attacker to cause a denial of service and may lead to remote code execution.
nodejs-getobject: Prototype pollution could result in DoS and RCE
Prototype pollution vulnerability in 'getobject' version 0.1.0 allows an attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'set-object-value' versions 0.0.0 through 0.0.5 allows an attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'predefine' versions 0.0.0 through 0.1.2 allows an attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'flattenizer' versions 0.0.5 through 1.0.5 allows an attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'shvl' versions 1.0.0 through 2.0.1 allows an attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'dset' versions 1.0.0 through 2.0.1 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'deep-set' versions 1.0.0 through 1.0.1 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'deepref' versions 1.1.1 through 1.2.1 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'set-in' versions 1.0.0 through 2.0.0 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'keyget' versions 1.0.0 through 2.2.0 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'object-hierarchy-access' versions 0.2.0 through 0.32.0 allows attacker to cause a denial of service and may lead to remote code execution.
Prototype pollution vulnerability in 'field' versions 0.0.1 through 1.0.1 allows attacker to cause a denial of service and may lead to remote code execution.
Cellinx NVT Web Server 5.0.0.014b.test 2019-09-05 allows a remote user to run commands as root via SetFileContent.cgi because authentication is on the client side.
A Server-Side Template Injection (SSTI) was discovered in Form.io 2.0.0. This leads to Remote Code Execution during deletion of the default Email template URL. NOTE: the email templating service was removed after 2020. Additionally, the vendor disputes this issue indicating this is sandboxed and only executable by admins.
A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.
A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.