A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. |
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface
via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service
condition on affected devices. Flashing with a firmware image may be required
to recover the CPU.
Successful exploitation requires an attacker to have network access to port
102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or
Multi Point Interfaces (MPI) to the device. No user interaction is required.
If no access protection is configured, no privileges are required to exploit
the security vulnerability. The vulnerability could allow causing a
denial of service condition of the core functionality of the CPU,
compromising the availability of the system. |
TeamViewer 10.x through 13.x allows remote attackers to bypass the brute-force authentication protection mechanism by skipping the "Cancel" step, which makes it easier to determine the correct value of the default 4-digit PIN. |
In Artifex Ghostscript before 9.24, gssetresolution and gsgetresolution allow attackers to have an unspecified impact. |
Amazon Web Services (AWS) FreeRTOS through 1.3.1, FreeRTOS up to V10.0.1 (with FreeRTOS+TCP), and WITTENSTEIN WHIS Connect middleware TCP/IP component allow remote attackers to leak information or execute arbitrary code because of a Buffer Overflow during generation of a protocol checksum in usGenerateProtocolChecksum and prvProcessIPPacket. |
Amazon Web Services (AWS) FreeRTOS through 1.3.1, FreeRTOS up to V10.0.1 (with FreeRTOS+TCP), and WITTENSTEIN WHIS Connect middleware TCP/IP component allow remote attackers to execute arbitrary code or leak information because of a Buffer Overflow during parsing of DNS\LLMNR packets in prvParseDNSReply. |
An issue was discovered in Artifex Ghostscript before 9.24. Incorrect "restoration of privilege" checking during handling of /invalidaccess exceptions could be used by attackers able to supply crafted PostScript to execute code using the "pipe" instruction. |
A prototype pollution vulnerability was found in lodash <4.17.11 where the functions merge, mergeWith, and defaultsDeep can be tricked into adding or modifying properties of Object.prototype. |
A bypass vulnerability in Active Storage >= 5.2.0 for Google Cloud Storage and Disk services allow an attacker to modify the `content-disposition` and `content-type` parameters which can be used in with HTML files and have them executed inline. Additionally, if combined with other techniques such as cookie bombing and specially crafted AppCache manifests, an attacker can gain access to private signed URLs within a specific storage path. This vulnerability has been fixed in version 5.2.1.1. |
In Twistlock AuthZ Broker 0.1, regular expressions are mishandled, as demonstrated by containers/aa/pause?aaa=\/start to bypass a policy in which "docker start" is allowed but "docker pause" is not allowed. |
An issue was discovered in Ruby before 2.3.8, 2.4.x before 2.4.5, 2.5.x before 2.5.2, and 2.6.x before 2.6.0-preview3. It does not taint strings that result from unpacking tainted strings with some formats. |
An issue was discovered in the OpenSSL library in Ruby before 2.3.8, 2.4.x before 2.4.5, 2.5.x before 2.5.2, and 2.6.x before 2.6.0-preview3. When two OpenSSL::X509::Name objects are compared using ==, depending on the ordering, non-equal objects may return true. When the first argument is one character longer than the second, or the second argument contains a character that is one less than a character in the same position of the first argument, the result of == will be true. This could be leveraged to create an illegitimate certificate that may be accepted as legitimate and then used in signing or encryption operations. |
XRef::fetch in XRef.cc in Xpdf 4.00 allows remote attackers to cause a denial of service (stack consumption) via a crafted pdf file, related to AcroForm::scanField, as demonstrated by pdftohtml. NOTE: this might overlap CVE-2018-7453. |
Google gVisor before 2018-08-23, within the seccomp sandbox, permits access to the renameat system call, which allows attackers to rename files on the host OS. |
The DEISER "Profields - Project Custom Fields" app before 6.0.2 for Jira has Incorrect Access Control. |
PowerAct Pro Master Agent for Windows Version 5.13 and earlier allows authenticated attackers to bypass access restriction to alter or edit unauthorized files via unspecified vectors. |
PgpoolAdmin 4.0 and earlier allows remote attackers to bypass the login authentication and obtain the administrative privilege of the PostgreSQL database via unspecified vectors. |
Toshiba Home gateway HEM-GW16A 1.2.9 and earlier, Toshiba Home gateway HEM-GW26A 1.2.9 and earlier may allow an attacker on the same network segment to access a non-documented developer screen to perform operations on the affected device. |
Toshiba Home gateway HEM-GW16A 1.2.9 and earlier, Toshiba Home gateway HEM-GW26A 1.2.9 and earlier allows an attacker on the same network segment to bypass access restriction to access the information and files stored on the affected device. |