In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator.
Search vulnerabilities
In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
In Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, when service ids allow user input, this could allow for SQL Injection and remote code execution. This is related to symfony/dependency-injection.
Default hidden Privileged Account Vulnerability in multiple XEROX devices
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
Blamer versions prior to 1.0.1 allows execution of arbitrary commands. It is possible to inject arbitrary commands as part of the arguments provided to blamer.
serial-number through 1.3.0 allows execution of arbritary commands. The "cmdPrefix" argument in serialNumber function is used by the "exec" function without any validation.
push-dir through 0.4.1 allows execution of arbritary commands. Arguments provided as part of the variable "opt.branch" is not validated before being provided to the "git" command within "index.js#L139". This could be abused by an attacker to inject arbitrary commands.
giting version prior to 0.0.8 allows execution of arbritary commands. The first argument "repo" of function "pull()" is executed by the package without any validation.
enpeem through 2.2.0 allows execution of arbitrary commands. The "options.dir" argument is provided to the "exec" function without any sanitization.
rpi through 0.0.3 allows execution of arbritary commands. The variable pinNumbver in function GPIO within src/lib/gpio.js is used as part of the arguement of exec function without any sanitization.
promise-probe before 0.10.0 allows remote attackers to perform a command injection attack. The file, outputFile and options functions can be controlled by users without any sanitization.
All versions of curling.js are vulnerable to Command Injection via the run function. The command argument can be controlled by users without any sanitization.
im-metadata through 3.0.1 allows remote attackers to execute arbitrary commands via the "exec" argument. It is possible to inject arbitrary commands as part of the metadata options which is given to the "exec" function.
im-resize through 2.3.2 allows remote attackers to execute arbitrary commands via the "exec" argument. The cmd argument used within index.js, can be controlled by user without any sanitization.