Search vulnerabilities

Results 425,959

CVE-2022-24335

JetBrains TeamCity before 2021.2 was vulnerable to a Time-of-check/Time-of-use (TOCTOU) race-condition attack in agent registration via XML-RPC.

CVSS 3.1 · 8.1 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-24334

In JetBrains TeamCity before 2021.2.1, the Agent Push feature allowed selection of any private key on the server.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-24333

In JetBrains TeamCity before 2021.2, blind SSRF via an XML-RPC call was possible.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-24332

In JetBrains TeamCity before 2021.2, a logout action didn't remove a Remember Me cookie.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-24331

In JetBrains TeamCity before 2021.1.4, GitLab authentication impersonation was possible.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2022-24330

In JetBrains TeamCity before 2021.2.1, a redirection to an external site was possible.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-24328

In JetBrains Hub before 2021.1.13956, an unprivileged user could perform DoS.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
Hub
CVE-2022-24327

In JetBrains Hub before 2021.1.13890, integration with JetBrains Account exposed an API key with excessive permissions.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
Hub
CVE-2022-24323

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
CVE-2022-24322

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
CVE-2022-24321

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
CVE-2022-24320

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

CVSS 3.1 · 5.9 Medium EPSS < 1% KEV · Not listed
CVE-2022-24319

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

CVSS 3.1 · 5.9 Medium EPSS < 1% KEV · Not listed
CVE-2022-24318

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
CVE-2022-24314

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

CVSS 3.1 · 7.5 High EPSS 18.2% KEV · Not listed
CVE-2022-24313

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

CVSS 3.1 · 9.8 Critical EPSS 44.6% KEV · Not listed