The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Search vulnerabilities
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm.
Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
AVEVA SuiteLink Server Improper Handling of Exceptional Conditions
Improper handling of exceptional conditions in SuiteLink server while processing command 0x01
Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute code in the context of the current process.
Philips IntelliBridge EC 40 and EC 80 Hub Use of Hard-coded Credentials
IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the bounds of a memory buffer, which may allow an attacker to execute arbitrary code.
Delta Electronics DIAEnergie Version 1.7.5 and prior is vulnerable to cross-site request forgery, which may allow an attacker to cause a user to carry out an action unintentionally.
FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.
AVEVA SuiteLink Server Null Pointer Dereference
Null pointer dereference in SuiteLink server while processing command 0x0b
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
AVEVA SuiteLink Server Null Pointer Dereference
Null pointer dereference in SuiteLink server while processing commands 0x04/0x0a
Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.
Panasonic FPWIN Pro, all Versions 7.5.1.1 and prior, allows an attacker to craft a project file specifying a URI that causes the XML parser to access the URI and embed the contents, which may allow the attacker to disclose information that is accessible in the context of the user executing software.
AVEVA SuiteLink Server Null Pointer Dereference
Null pointer dereference in SuiteLink server while processing command 0x07
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.
AVEVA SuiteLink Server Null Pointer Dereference
Null pointer dereference in SuiteLink server while processing commands 0x03/0x10
AVEVA SuiteLink Server Buffer Overflow
Heap-based buffer overflow in SuiteLink server while processing commands 0x05/0x06