Search vulnerabilities

Results 425,864

CVE-2021-27438

The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Ge
CVE-2021-27437

The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1).

CVSS 3.1 · 9.1 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2021-27436

WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-27429

Texas Instruments TI-RTOS Integer Overflow or Wraparound

Texas Instruments TI-RTOS returns a valid pointer to a small buffer on extremely large values. This can trigger an integer overflow vulnerability in 'HeapTrack_alloc' and result in code execution.

CVSS 3.1 · 7.4 High EPSS < 1% KEV · Not listed
Vendors
Ti
Products
Cc3200 Cc3220r Cc3220s and 11 more
CVE-2021-27413

Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 10.0% KEV · Not listed
Vendors
Products
CVE-2021-27412

Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-27410

The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

CVSS 3.1 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
CVE-2021-27408

The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

CVSS 3.1 · 7.5 High EPSS 1.7% KEV · Not listed
Vendors
CVE-2021-27402

The SAS Admin portal of Mitel MiCollab before 9.2 FP2 could allow an unauthenticated attacker to access (view and modify) user data by injecting arbitrary directory paths due to improper URL validation, aka Directory Traversal.

CVSS 3.1 · 6.5 Medium EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2021-27401

The Join Meeting page of Mitel MiCollab Web Client before 9.2 FP2 could allow an attacker to access (view and modify) user data by executing arbitrary code due to insufficient input validation, aka Cross-Site Scripting (XSS).

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-27400

vault: TLS certificates not validated when connecting to Cassandra clusters

HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-27399

A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)

CVSS 3.1 · 7.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2021-27398

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)

CVSS 3.1 · 7.8 High EPSS 1.5% KEV · Not listed
Vendors
CVE-2021-27397

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)

CVSS 3.1 · 7.8 High EPSS 1.4% KEV · Not listed
Vendors
CVE-2021-27396

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279)

CVSS 3.1 · 7.8 High EPSS 1.5% KEV · Not listed
Vendors