Filtered by vendor Schneider-electric Subscriptions
Total 753 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-6813 1 Schneider-electric 4 Bmxnor0200h, Bmxnor0200h Firmware, Modicon M340 and 1 more 2024-08-04 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.
CVE-2019-6819 1 Schneider-electric 38 Bmeh582040, Bmeh582040c, Bmeh584040 and 35 more 2024-08-04 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.
CVE-2019-6811 1 Schneider-electric 4 Modicon Quantum 140noe77101, Modicon Quantum 140noe77101 Firmware, Modicon Quantum 140noe77111 and 1 more 2024-08-04 7.5 High
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.
CVE-2019-6816 1 Schneider-electric 2 Modicon Quantum, Modicon Quantum Firmware 2024-08-04 N/A
In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol.
CVE-2019-6828 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-04 7.5 High
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.
CVE-2019-6815 1 Schneider-electric 2 Modicon Quantum, Modicon Quantum Firmware 2024-08-04 N/A
In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol.
CVE-2019-6814 1 Schneider-electric 14 Net5500, Net5500 Firmware, Net5501 and 11 more 2024-08-04 9.8 Critical
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.
CVE-2019-6809 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-04 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.
CVE-2019-6822 1 Schneider-electric 1 Zelio Soft 2 2024-08-04 7.8 High
A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.
CVE-2019-6808 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-04 9.8 Critical
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
CVE-2019-6807 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-04 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus.
CVE-2019-6837 1 Schneider-electric 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more 2024-08-04 9.1 Critical
A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL.
CVE-2019-6812 1 Schneider-electric 2 Bmx-nor-0200h, Bmx-nor-0200h Firmware 2024-08-04 7.2 High
A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.
CVE-2020-28216 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-08-04 7.5 High
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.
CVE-2020-28221 1 Schneider-electric 42 Ecostruxure Operator Terminal Expert, Gp-4104g, Gp-4104w and 39 more 2024-08-04 9.8 Critical
A CWE-20: Improper Input Validation vulnerability exists in EcoStruxureâ„¢ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.
CVE-2020-28213 1 Schneider-electric 1 Ecostruxure Control Expert 2024-08-04 8.8 High
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
CVE-2020-28219 1 Schneider-electric 2 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-08-04 7.8 High
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
CVE-2020-28220 1 Schneider-electric 4 Modicon M258, Modicon M258 Firmware, Somachine and 1 more 2024-08-04 6.8 Medium
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.
CVE-2020-28217 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-08-04 7.5 High
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.
CVE-2020-28209 2 Microsoft, Schneider-electric 2 Windows, Enterprise Server Installer 2024-08-04 7.0 High
A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location.