Search vulnerabilities

Results 426,214

CVE-2020-12528

An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2. Improper use of access validation allows a logged in user to kill web2go sessions in the account he should not have access to.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12527

Improper Access Validation in products of MB connect line and Helmholz

An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.

CVSS 3.1 · 6.5 Medium EPSS 1.0% KEV · Not listed
Products
CVE-2020-12526

BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server

TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the OPC UA server is no longer responsive to any client. This is without effect to the real-time functionality of IPCs.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12524

Phoenix Contact BTP Touch Panels uncontrolled resource consumption

Uncontrolled Resource Consumption can be exploited to cause the Phoenix Contact HMIs BTP 2043W, BTP 2070W and BTP 2102W in all versions to become unresponsive and not accurately update the display content (Denial of Service).

CVSS 3.1 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2020-12523

Phoenix Contact mGuard Devices versions before 8.8.3: LAN ports get functional after reboot even if they are disabled in the device configuration

On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports get functional independent from their configuration setting: Missing Initialization of Resource

CVSS 3.1 · 5.4 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12522

Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions <=FW10

The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.

CVSS 3.1 · 10 Critical EPSS 3.1% KEV · Not listed
Vendors
CVE-2020-12521

Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack.

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12519

Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use this vulnerability i.e. to open a reverse shell with root privileges.

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12518

Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12517

Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website (local privilege escalation).

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website (local privilege escalation).

CVSS 3.1 · 8.8 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2020-12516

WAGO: PLC families 750-88x and 750-352 prone to DoS attack

Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.

CVSS 3.1 · 7.5 High EPSS 1.9% KEV · Not listed
Vendors
Products
CVE-2020-12510

Beckhoff: Privilege Escalation through TwinCat System

The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for automatic execution upon log in of a user. If a less privileged user has a local account he or she can replace TcSysUI.exe. It will be executed automatically by another user during login. This is also true for users with administrative access. Consequently, a less privileged user can trick a higher privileged user into executing code he or she modified this way. By default Beckhoff’s IPCs are shipped with TwinCAT software installed this way and with just a single local user configured. Thus the vulnerability exists if further less privileged users have been added.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12506

WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions <= FW03

Improper Authentication vulnerability in WAGO 750-8XX series with FW version <= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions.

CVSS 3.1 · 9.1 Critical EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2020-12505

WAGO: Vulnerability in web-based authentication in WAGO 750-8XX Version <= FW07

Improper Authentication vulnerability in WAGO 750-8XX series with FW version <= FW07 allows an attacker to change some special parameters without authentication. This issue affects: WAGO 750-852, WAGO 750-880/xxx-xxx, WAGO 750-881, WAGO 750-831/xxx-xxx, WAGO 750-882, WAGO 750-885/xxx-xxx, WAGO 750-889 in versions FW07 and below.

CVSS 3.1 · 8.2 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2020-12504

Pepperl+Fuchs improper authorization affects multiple Comtrol RocketLinx products

Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) and ICRL-M-8RJ45/4SFP-G-DIN, ICRL-M-16RJ45/4CP-G-DIN FW 1.2.3 and below has an active TFTP-Service.

CVSS 3.1 · 9.8 Critical EPSS 3.0% KEV · Not listed