A privilege escalation flaw allows a malicious, authenticated, privileged CLI user to escalate their privileges on the system and gain full control over the SMG appliance. This affects SMG prior to 10.7.4.
Search vulnerabilities
Symantec Endpoint Detection & Response, prior to 4.5, may be susceptible to an information disclosure issue, which is a type of vulnerability that could potentially allow unauthorized access to data.
An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2. There is an XSS issue in the redirect.php allowing an attacker to inject code via a get parameter.
An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2 There is a SSRF in the LDAP access check, allowing an attacker to scan for open ports.
An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2. Improper use of access validation allows a logged in user to kill web2go sessions in the account he should not have access to.
Improper Access Validation in products of MB connect line and Helmholz
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.
BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server
TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the OPC UA server is no longer responsive to any client. This is without effect to the real-time functionality of IPCs.
WAGO/M&M Software Deserialization of untrusted data in fdtCONTAINER component
M&M Software fdtCONTAINER Component in versions below 3.5.20304.x and between 3.6 and 3.6.20304.x is vulnerable to deserialization of untrusted data in its project storage.
Phoenix Contact BTP Touch Panels uncontrolled resource consumption
Uncontrolled Resource Consumption can be exploited to cause the Phoenix Contact HMIs BTP 2043W, BTP 2070W and BTP 2102W in all versions to become unresponsive and not accurately update the display content (Denial of Service).
Phoenix Contact mGuard Devices versions before 8.8.3: LAN ports get functional after reboot even if they are disabled in the device configuration
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports get functional independent from their configuration setting: Missing Initialization of Resource
Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions <=FW10
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use this vulnerability i.e. to open a reverse shell with root privileges.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges.
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website (local privilege escalation).
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website (local privilege escalation).
WAGO: PLC families 750-88x and 750-352 prone to DoS attack
Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.
Pepper+Fuchs Comtrol IO-Link Master NULL Pointer Dereference
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a NULL Pointer Dereference that leads to a DoS in discoveryd
Pepper+Fuchs Comtrol IO-Link Master OS Command Injection
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection.
Pepper+Fuchs Comtrol IO-Link Master Cross-Site Scripting
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated reflected POST Cross-Site Scripting
Pepper+Fuchs Comtrol IO-Link Master Cross-Site Request Forgery
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface.