Search vulnerabilities

Results 425,880

CVE-2019-6836

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
CVE-2019-6835

A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.

CVSS 3.1 · 5.4 Medium EPSS < 1% KEV · Not listed
CVE-2019-6834

A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0)

CVSS 3.1 · 7.3 High EPSS 1.0% KEV · Not listed
Products
CVE-2019-6832

A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.

CVSS 3.1 · 8.3 High EPSS 1.5% KEV · Not listed
Products
CVE-2019-6831

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.

CVSS 3.1 · 8.6 High EPSS 1.4% KEV · Not listed
CVE-2019-6830

A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller.

CVSS 3.1 · 5.9 Medium EPSS 1.1% KEV · Not listed
CVE-2019-6828

A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.

CVSS 3.1 · 7.5 High EPSS 1.5% KEV · Not listed
CVE-2019-6826

A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product.

CVSS 3.1 · 7.8 High EPSS 1.2% KEV · Not listed
Products
CVE-2019-6825

A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0.

CVSS 3.1 · 7.8 High EPSS 1.2% KEV · Not listed
Products
CVE-2019-6824

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

CVSS 3.1 · 9.8 Critical EPSS 4.5% KEV · Not listed
Products
CVE-2019-6823

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

CVSS 3.1 · 9.8 Critical EPSS 5.0% KEV · Not listed
Products
CVE-2019-6822

A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.

CVSS 3.1 · 7.8 High EPSS 3.7% KEV · Not listed
Products
CVE-2019-6821

CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum.

CVSS 3.1 · 6.5 Medium EPSS 1.9% KEV · Not listed
CVE-2019-6815

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol.

CVSS 3.0 · 9.1 Critical EPSS 1.4% KEV · Not listed
CVE-2019-6814

A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.

CVSS 3.1 · 9.8 Critical EPSS 36.6% KEV · Not listed
Products
CVE-2019-6813

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.

CVSS 3.1 · 7.5 High EPSS 2.1% KEV · Not listed
CVE-2019-6811

An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed