Search vulnerabilities

Results 426,448

CVE-2019-10982

Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap.

CVSS 3.1 · 7.8 High EPSS 1.4% KEV · Not listed
Vendors
CVE-2019-10980

A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

CVSS 3.1 · 7.8 High EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2019-10979

SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.

CVSS 3.0 · 9.8 Critical EPSS 3.4% KEV · Not listed
Vendors
CVE-2019-10977

In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 3.5% KEV · Not listed
CVE-2019-10974

NREL EnergyPlus, Versions 8.6.0 and possibly prior versions, The application fails to prevent an exception handler from being overwritten with arbitrary code.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-10973

Quest KACE, all versions prior to version 8.0.x, 8.1.x, and 9.0.x, allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface.

CVSS 3.0 · 7.2 High EPSS 2.4% KEV · Not listed
Vendors
CVE-2019-10972

Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
CVE-2019-10971

The application (Network Configurator for DeviceNet Safety 3.41 and prior) searches for resources by means of an untrusted search path that could execute a malicious .dll file not under the application's direct control and outside the intended directories.

CVSS 3.0 · 7.8 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2019-10970

In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.

CVSS 3.1 · 9.8 Critical EPSS 4.6% KEV · Not listed
CVE-2019-10969

Moxa EDR 810, all versions 5.1 and prior, allows an authenticated attacker to abuse the ping feature to execute unauthorized commands on the router, which may allow an attacker to perform remote code execution.

CVSS 3.1 · 7.2 High EPSS 10.6% KEV · Not listed
Vendors
CVE-2019-10968

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.

CVSS 3.1 · 4.4 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-10967

In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a stack-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileges.

CVSS 3.1 · 8.8 High EPSS 3.7% KEV · Not listed
Vendors
CVE-2019-10966

In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.

CVSS 3.1 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Ge
CVE-2019-10965

In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a heap-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long command to the FTP service, which may cause memory corruption that halts the controller or leads to remote code execution and escalation of privileges.

CVSS 3.1 · 8.8 High EPSS 3.6% KEV · Not listed
Vendors
CVE-2019-10963

Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user.

CVSS 3.1 · 4.3 Medium EPSS 6.5% KEV · Not listed
Vendors
CVE-2019-10962

BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device.

CVSS 3.1 · 5.3 Medium EPSS 1.7% KEV · Not listed
Vendors
Bd
CVE-2019-10961

In Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution.

CVSS 3.1 · 8.8 High EPSS 4.1% KEV · Not listed
Vendors