Search vulnerabilities

Results 425,871

CVE-2018-7529

A Deserialization of Untrusted Data issue was discovered in OSIsoft PI Data Archive versions 2017 and prior. Unauthenticated users may modify deserialized data to send custom requests that crash the server.

CVSS 3.0 · 7.5 High EPSS 2.1% KEV · Not listed
Vendors
Products
CVE-2018-7525

In Omron CX-Supervisor Versions 3.30 and prior, processing a malformed packet by a certain executable may cause an untrusted pointer dereference vulnerability.

CVSS 3.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7523

In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a double free vulnerability.

CVSS 3.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7521

In Omron CX-Supervisor Versions 3.30 and prior, use after free vulnerabilities can be exploited when CX Supervisor parses a specially crafted project file.

CVSS 3.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7520

An improper access control vulnerability has been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which could allow a full configuration download, including passwords.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
CVE-2018-7519

In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a heap-based buffer overflow.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7517

In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause an out of bounds vulnerability.

CVSS 3.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7515

In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can be exploited when CX Supervisor indirectly calls an initialized pointer when parsing malformed packets.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7514

Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7513

In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a stack-based buffer overflow.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-7511

In Eaton ELCSoft versions 2.04.02 and prior, there are multiple cases where specially crafted files could cause a buffer overflow which, in turn, may allow remote execution of arbitrary code.

CVSS 3.0 · 5.3 Medium EPSS 2.0% KEV · Not listed
Vendors
Products