Search vulnerabilities

Results 425,868

CVE-2018-7244

An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.

CVSS 3.0 · 5.3 Medium EPSS 1.0% KEV · Not listed
CVE-2018-7243

An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.

CVSS 3.0 · 9.8 Critical EPSS 2.8% KEV · Not listed
CVE-2018-7242

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
CVE-2018-7240

A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.

CVSS 3.0 · 8.8 High EPSS 3.2% KEV · Not listed
CVE-2018-7239

A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.

CVSS 3.0 · 7.8 High EPSS 2.8% KEV · Not listed
Products
CVE-2018-7238

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.

CVSS 3.1 · 9.8 Critical EPSS 2.8% KEV · Not listed
CVE-2018-7237

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'

CVSS 3.1 · 9.1 Critical EPSS 1.7% KEV · Not listed
CVE-2018-7236

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.

CVSS 3.1 · 8.1 High EPSS 1.3% KEV · Not listed
CVE-2018-7235

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'

CVSS 3.1 · 7.5 High EPSS 1.6% KEV · Not listed
CVE-2018-7233

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

CVSS 3.1 · 9.8 Critical EPSS 2.0% KEV · Not listed
CVE-2018-7232

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

CVSS 3.1 · 9.8 Critical EPSS 2.0% KEV · Not listed
CVE-2018-7231

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

CVSS 3.1 · 9.8 Critical EPSS 2.0% KEV · Not listed
CVE-2018-7229

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

CVSS 3.1 · 9.8 Critical EPSS 2.2% KEV · Not listed
CVE-2018-7228

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

CVSS 3.1 · 9.8 Critical EPSS 2.2% KEV · Not listed
CVE-2018-7227

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.

CVSS 3.1 · 5.3 Medium EPSS 1.2% KEV · Not listed
CVE-2018-7226

libvncserver: integer overflow in vcSetXCutTextProc in VNConsole.c

An issue was discovered in vcSetXCutTextProc() in VNConsole.c in LinuxVNC and VNCommand from the LibVNC/vncterm distribution through 0.9.10. Missing sanitization of the client-specified message length may cause integer overflow or possibly have unspecified other impact via a specially crafted VNC packet.

CVSS 3.0 · 9.8 Critical EPSS 2.6% KEV · Not listed
Vendors
Products
CVE-2018-7225

libvncserver: Improper input sanitization in rfbProcessClientNormalMessage in rfbserver.c

An issue was discovered in LibVNCServer through 0.9.11. rfbProcessClientNormalMessage() in rfbserver.c does not sanitize msg.cct.length, leading to access to uninitialized and potentially sensitive data or possibly unspecified other impact (e.g., an integer overflow) via specially crafted VNC packets.

CVSS 3.0 · 9.8 Critical EPSS 6.1% KEV · Not listed