Search vulnerabilities

Results 427,691

CVE-2018-5470

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified, which may allow an authorized local user to execute arbitrary code and escalate their level of privileges.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-5469

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication.

CVSS 3.0 · 9.8 Critical EPSS 2.9% KEV · Not listed
Vendors
CVE-2018-5468

Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code

CVSS 3.0 · 9.8 Critical EPSS 4.5% KEV · Not listed
Vendors
CVE-2018-5467

An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An information exposure through query strings vulnerability in the web interface has been identified, which may allow an attacker to impersonate a legitimate user.

CVSS 3.0 · 6.5 Medium EPSS 1.3% KEV · Not listed
Vendors
CVE-2018-5466

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

CVSS 3.0 · 7.5 High EPSS 1.9% KEV · Not listed
Vendors
CVE-2018-5465

A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.

CVSS 3.0 · 8.8 High EPSS 1.7% KEV · Not listed
Vendors
CVE-2018-5464

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

CVSS 3.0 · 7.5 High EPSS 1.9% KEV · Not listed
Vendors
CVE-2018-5463

A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-5462

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

CVSS 3.0 · 7.5 High EPSS 1.9% KEV · Not listed
Vendors
CVE-2018-5461

An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-5459

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.

CVSS 3.0 · 9.8 Critical EPSS 2.7% KEV · Not listed
Vendors
CVE-2018-5458

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.

CVSS 3.0 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
CVE-2018-5457

A uncontrolled search path element issue was discovered in Vyaire Medical CareFusion Upgrade Utility used with Windows XP systems, Versions 2.0.2.2 and prior versions. A successful exploit of this vulnerability requires the local user to install a crafted DLL on the target machine. The application loads the DLL and gives the attacker access at the same privilege level as the application.

CVSS 3.0 · 7.0 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-5455

A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.

CVSS 3.0 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
CVE-2018-5454

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.

CVSS 3.0 · 8.1 High EPSS 3.4% KEV · Not listed
Vendors
CVE-2018-5452

A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWave Micro [ProConOS v.4.01.280] firmware: CWM v.05.78.00 and prior. A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode.

CVSS 3.1 · 7.5 High EPSS 2.2% KEV · Not listed
Vendors
CVE-2018-5451

In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.

CVSS 3.0 · 9.8 Critical EPSS 2.6% KEV · Not listed
Vendors
CVE-2018-5447

An Improper Input Validation issue was discovered in Nari PCS-9611 relay. An improper input validation vulnerability has been identified that affects a service within the software that may allow a remote attacker to arbitrarily read/access system resources and affect the availability of the system.

CVSS 3.0 · 9.8 Critical EPSS 2.4% KEV · Not listed
Vendors