Search vulnerabilities

Results 425,877

CVE-2018-17917

All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps.

CVSS 3.0 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
CVE-2018-17916

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.

CVSS 3.1 · 9.8 Critical EPSS 3.7% KEV · Not listed
Vendors
CVE-2018-17915

All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeye service and firmware update communication. This could allow an attacker to eavesdrop on video feeds, steal XMeye login credentials, or impersonate the update server with malicious update code.

CVSS 3.0 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors
CVE-2018-17914

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime.

CVSS 3.1 · 9.8 Critical EPSS 4.6% KEV · Not listed
Vendors
CVE-2018-17913

A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17912

An XXE vulnerability exists in CASE Suite Versions 3.10 and prior when processing parameter entities, which may allow remote file disclosure.

CVSS 3.0 · 7.5 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17911

LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.

CVSS 3.1 · 7.8 High EPSS 3.2% KEV · Not listed
Vendors
Products
CVE-2018-17910

WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution.

CVSS 3.0 · 7.8 High EPSS 5.2% KEV · Not listed
Vendors
Products
CVE-2018-17909

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17908

WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17907

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with the value of an offset, an attacker can force the application to read a value outside of an array.

CVSS 3.0 · 3.3 Low EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17906

Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-17905

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object.

CVSS 3.0 · 7.8 High EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2018-17904

Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code.

CVSS 3.0 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17902

Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.

CVSS 3.0 · 5.3 Medium EPSS 1.1% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17901

LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17900

Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17899

LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.

CVSS 3.0 · 8.8 High EPSS 8.1% KEV · Not listed
Vendors
Products