Search vulnerabilities

Results 425,892

CVE-2018-17913

A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17912

An XXE vulnerability exists in CASE Suite Versions 3.10 and prior when processing parameter entities, which may allow remote file disclosure.

CVSS 3.0 · 7.5 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17911

LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.

CVSS 3.1 · 7.8 High EPSS 3.2% KEV · Not listed
Vendors
Products
CVE-2018-17910

WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution.

CVSS 3.0 · 7.8 High EPSS 5.2% KEV · Not listed
Vendors
Products
CVE-2018-17909

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17908

WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17907

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with the value of an offset, an attacker can force the application to read a value outside of an array.

CVSS 3.0 · 3.3 Low EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17906

Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-17905

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object.

CVSS 3.0 · 7.8 High EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2018-17904

Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code.

CVSS 3.0 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-17902

Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.

CVSS 3.0 · 5.3 Medium EPSS 1.1% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17901

LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-17900

Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17899

LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.

CVSS 3.0 · 8.8 High EPSS 8.1% KEV · Not listed
Vendors
Products
CVE-2018-17898

Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable.

CVSS 3.0 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17897

LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 6.0% KEV · Not listed
Vendors
Products
CVE-2018-17896

Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work.

CVSS 3.0 · 8.1 High EPSS 1.2% KEV · Not listed
Vendors
Products
Fcj Fcj Firmware Fcn-100 and 5 more
CVE-2018-17895

LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 4.8% KEV · Not listed
Vendors
Products
CVE-2018-17894

NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.

CVSS 3.0 · 9.8 Critical EPSS 2.4% KEV · Not listed
Vendors