CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.

CVSS 3.0 · 5.3 Medium EPSS 1.7% KEV · Not listed
Vendors
CVE-2018-14802

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 3.6% KEV · Not listed
Vendors
Products
CVE-2018-14801

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

CVSS 3.0 · 6.2 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-14800

Delta Electronics ISPSoft version 3.0.5 and prior allow an attacker, by opening a crafted file, to cause the application to read past the boundary allocated to a stack object, which could allow execution of code under the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-14798

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure.

CVSS 3.0 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14797

Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 allow a specially crafted DLL file to be placed in the search path and loaded as an internal and valid DLL, which may allow arbitrary code execution.

CVSS 3.1 · 7.8 High EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2018-14796

Tec4Data SmartCooler, all versions prior to firmware 180806, the device responds to a remote unauthenticated reboot command that may be used to perform a denial of service attack.

CVSS 3.0 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2018-14795

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable due to improper path validation which may allow an attacker to replace executable files.

CVSS 3.0 · 8.8 High EPSS 2.2% KEV · Not listed
Vendors
Products
CVE-2018-14793

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable to a buffer overflow exploit through an open communication port to allow arbitrary code execution.

CVSS 3.0 · 8.8 High EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2018-14792

WECON PLC Editor version 1.3.3U may allow an attacker to execute code under the current process when processing project files.

CVSS 3.0 · 6.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14791

Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 may allow non-administrative users to change executable and library files on the affected products.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-14790

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.

CVSS 3.0 · 9.8 Critical EPSS 5.4% KEV · Not listed
Vendors
Products
CVE-2018-14789

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges.

CVSS 3.1 · 6.7 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-14787

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-14786

Becton, Dickinson and Company (BD) Alaris Plus medical syringe pumps (models Alaris GS, Alaris GH, Alaris CC, and Alaris TIVA) versions 2.3.6 and prior are affected by an improper authentication vulnerability where the software does not perform authentication for functionality that requires a provable user identity, where it may allow a remote attacker to gain unauthorized access to various Alaris Syringe pumps and impact the intended operation of the pump when it is connected to a terminal server via the serial port.

CVSS 3.0 · 9.4 Critical EPSS 2.9% KEV · Not listed
Vendors
Bd
Products
CVE-2018-14785

NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The directory of the device is listed openly without authentication.

CVSS 3.0 · 7.5 High EPSS 2.1% KEV · Not listed
Vendors
CVE-2018-14784

NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device is vulnerable to several cross-site scripting attacks, allowing a remote attacker to run arbitrary code on the device.

CVSS 3.0 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors