CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. |
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. |
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution. |
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function. |
A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function. |
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function. |
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function. |
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function. |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. |
Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. |