| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the function is running.
|
| Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error. |
| Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file. |
| Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. |
| Out-of-bounds Read vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. |
| Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors. |
| Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors. |