Filtered by vendor Juniper
Subscriptions
Filtered by product Mx10003
Subscriptions
Total
56 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-22178 | 1 Juniper | 45 Junos, Mx10, Mx10000 and 42 more | 2024-09-17 | 7.5 High |
A Stack-based Buffer Overflow vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on MX Series and SRX series allows an unauthenticated networked attacker to cause a flowd crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can be triggered by a specific Session Initiation Protocol (SIP) invite packet if the SIP ALG is enabled. Due to this, the PIC will be rebooted and all traffic that traverses the PIC will be dropped. This issue affects: Juniper Networks Junos OS 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2; 21.3 versions prior to 21.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1. | ||||
CVE-2020-1680 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-17 | 5.3 Medium |
On Juniper Networks MX Series with MS-MIC or MS-MPC card configured with NAT64 configuration, receipt of a malformed IPv6 packet may crash the MS-PIC component on MS-MIC or MS-MPC. This issue occurs when a multiservice card is translating the malformed IPv6 packet to IPv4 packet. An unauthenticated attacker can continuously send crafted IPv6 packets through the device causing repetitive MS-PIC process crashes, resulting in an extended Denial of Service condition. This issue affects Juniper Networks Junos OS on MX Series: 15.1 versions prior to 15.1R7-S7; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S11, 17.4R3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D53, 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2. | ||||
CVE-2020-1633 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-17 | 7.4 High |
Due to a new NDP proxy feature for EVPN leaf nodes introduced in Junos OS 17.4, crafted NDPv6 packets could transit a Junos device configured as a Broadband Network Gateway (BNG) and reach the EVPN leaf node, causing a stale MAC address entry. This could cause legitimate traffic to be discarded, leading to a Denial of Service (DoS) condition. This issue only affects Junos OS 17.4 and later releases. Prior releases do not support this feature and are unaffected by this vulnerability. This issue only affects IPv6. IPv4 ARP proxy is unaffected by this vulnerability. This issue affects Juniper Networks Junos OS: 17.4 versions prior to 17.4R2-S9, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S9 on MX Series; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3 on MX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S2, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series. | ||||
CVE-2021-0202 | 1 Juniper | 17 Ex9200, Junos, Mx10 and 14 more | 2024-09-17 | 7.5 High |
On Juniper Networks MX Series and EX9200 Series platforms with Trio-based MPC (Modular Port Concentrator) where Integrated Routing and Bridging (IRB) interface is configured and it is mapped to a VPLS instance or a Bridge-Domain, certain network events at Customer Edge (CE) device may cause memory leak in the MPC which can cause an out of memory and MPC restarts. When this issue occurs, there will be temporary traffic interruption until the MPC is restored. An administrator can use the following CLI command to monitor the status of memory usage level of the MPC: user@device> show system resource-monitor fpc FPC Resource Usage Summary Free Heap Mem Watermark : 20 % Free NH Mem Watermark : 20 % Free Filter Mem Watermark : 20 % * - Watermark reached Slot # % Heap Free RTT Average RTT 1 87 PFE # % ENCAP mem Free % NH mem Free % FW mem Free 0 NA 88 99 1 NA 89 99 When the issue is occurring, the value of “% NH mem Free” will go down until the MPC restarts. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3R3-S8; 17.4R3-S2; 18.2R3-S4, 18.2R3-S5; 18.3R3-S2, 18.3R3-S3; 18.4 versions starting from 18.4R3-S1 and later versions prior to 18.4R3-S6; 19.2 versions starting from 19.2R2 and later versions prior to 19.2R3-S1; 19.4 versions starting from 19.4R2 and later versions prior to 19.4R2-S3, 19.4R3; 20.2 versions starting from 20.2R1 and later versions prior to 20.2R1-S3, 20.2R2. This issue does not affect Juniper Networks Junos OS: 18.1, 19.1, 19.3, 20.1. | ||||
CVE-2019-0063 | 1 Juniper | 18 Junos, Mx10, Mx10003 and 15 more | 2024-09-17 | 6.5 Medium |
When an MX Series Broadband Remote Access Server (BRAS) is configured as a Broadband Network Gateway (BNG) with DHCPv6 enabled, jdhcpd might crash when receiving a specific crafted DHCP response message on a subscriber interface. The daemon automatically restarts without intervention, but continuous receipt of specific crafted DHCP messages will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue only affects systems configured with DHCPv6 enabled. DHCPv4 is unaffected by this issue. This issue affects Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S5 on MX Series; 16.1 versions prior to 16.1R7-S5 on MX Series; 16.2 versions prior to 16.2R2-S10 on MX Series; 17.1 versions prior to 17.1R3-S1 on MX Series; 17.2 versions prior to 17.2R3-S2 on MX Series; 17.3 versions prior to 17.3R3-S6 on MX Series; 17.4 versions prior to 17.4R2-S5, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S6 on MX Series; 18.2 versions prior to 18.2R2-S4, 18.2R3 on MX Series; 18.2X75 versions prior to 18.2X75-D50 on MX Series; 18.3 versions prior to 18.3R1-S5, 18.3R3 on MX Series; 18.4 versions prior to 18.4R2 on MX Series; 19.1 versions prior to 19.1R1-S2, 19.1R2 on MX Series. | ||||
CVE-2021-0238 | 1 Juniper | 15 Junos, Mx10, Mx10000 and 12 more | 2024-09-16 | 5.5 Medium |
When a MX Series is configured as a Broadband Network Gateway (BNG) based on Layer 2 Tunneling Protocol (L2TP), executing certain CLI command may cause the system to run out of disk space, excessive disk usage may cause other complications. An administrator can use the following CLI command to monitor the available disk space: user@device> show system storage Filesystem Size Used Avail Capacity Mounted on /dev/gpt/junos 19G 18G 147M 99% /.mount <<<<< running out of space tmpfs 21G 16K 21G 0% /.mount/tmp tmpfs 5.3G 1.7M 5.3G 0% /.mount/mfs This issue affects Juniper Networks Junos OS on MX Series: 17.3R1 and later versions prior to 17.4R3-S5, 18.1 versions prior to 18.1R3-S13, 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S7; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R1-S1, 20.4R2; This issue does not affect Juniper Networks Junos OS versions prior to 17.3R1. | ||||
CVE-2022-22207 | 1 Juniper | 18 Junos, Mx10, Mx10000 and 15 more | 2024-09-16 | 7.5 High |
A Use After Free vulnerability in the Advanced Forwarding Toolkit (AFT) manager process (aftmand) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a kernel crash due to intensive polling of Abstracted Fabric (AF) interface statistics and thereby a Denial of Service (DoS). Continued gathering of AF interface statistics will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS on MX Series: 20.1 versions later than 20.1R1; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; 21.2 versions prior to 21.2R2. | ||||
CVE-2021-31379 | 1 Juniper | 18 Junos, Mx10, Mx10000 and 15 more | 2024-09-16 | 7.5 High |
An Incorrect Behavior Order vulnerability in the MAP-E automatic tunneling mechanism of Juniper Networks Junos OS allows an attacker to send certain malformed IPv4 or IPv6 packets to cause a Denial of Service (DoS) to the PFE on the device which is disabled as a result of the processing of these packets. Continued receipt and processing of these malformed IPv4 or IPv6 packets will create a sustained Denial of Service (DoS) condition. This issue only affects MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. An indicator of compromise is the output: FPC ["FPC ID" # e.g. "0"] PFE #{PFE ID # e.g. "1"] : Fabric Disabled Example: FPC 0 PFE #1 : Fabric Disabled when using the command: show chassis fabric fpcs An example of a healthy result of the command use would be: user@device-re1> show chassis fabric fpcs Fabric management FPC state: FPC 0 PFE #0 Plane 0: Plane enabled Plane 1: Plane enabled Plane 2: Plane enabled Plane 3: Plane enabled Plane 4: Plane enabled Plane 5: Plane enabled Plane 6: Plane enabled Plane 7: Plane enabled This issue affects: Juniper Networks Junos OS on MX Series with MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S8, 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1. | ||||
CVE-2021-0290 | 1 Juniper | 26 Ex9200, Ex9204, Ex9208 and 23 more | 2024-09-16 | 6.5 Medium |
Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition. This issue is platform-specific and affects the following platforms and line cards: * MPC7E/8E/9E and MPC10E on MX240, MX480, MX960, MX2008, MX2010, and MX2020 * MX204, MX10003, MX10008, MX10016 * EX9200, EX9251 * SRX4600 No other products or platforms are affected by this vulnerability. An indication of this issue occurring can be seen in the system log messages, as shown below: user@host> show log messages | match "Failed to complete DFE tuning" fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3) and interface will be in a permanently down state: user@host> show interfaces et-4/1/6 terse Interface Admin Link Proto Local Remote et-4/1/6 up down et-4/1/6.0 up down aenet --> ae101.0 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S7 on MX Series; 17.1R1 and later versions prior to 17.2R3-S3 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S11, 17.4R3-S1 on MX Series, SRX4600; 18.1 versions prior to 18.1R3-S10 on MX Series, EX9200 Series, SRX4600; 18.2 versions prior to 18.2R3-S3 on MX Series, EX9200 Series, SRX4600; 18.3 versions prior to 18.3R3-S1 on MX Series, EX9200 Series, SRX4600; 18.4 versions prior to 18.4R2-S3, 18.4R3 on MX Series, EX9200 Series, SRX4600; 19.1 versions prior to 19.1R2-S1, 19.1R3 on MX Series, EX9200 Series, SRX4600; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series, EX9200 Series, SRX4600; 19.3 versions prior to 19.3R2 on MX Series, EX9200 Series, SRX4600. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1. | ||||
CVE-2020-1649 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-16 | 7.5 High |
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of small fragments requiring reassembly, generating the following error messages: [LOG: Err] MQSS(2): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[2:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(2): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1960, QID 0 [LOG: Err] MQSS(2): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0xc38fb1 [LOG: Notice] Error: /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(2), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D34, 18.2X75-D41, 18.2X75-D53, 18.2X75-D65, 18.2X75-D430 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2 on MX Series; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability. | ||||
CVE-2021-0264 | 1 Juniper | 21 Junos, Junos Os Evolved, Mx10 and 18 more | 2024-09-16 | 5.9 Medium |
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulletin TSB17931 (login required). This issue affects: Juniper Networks Junos OS on MX Series: 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2. Juniper Networks Junos OS Evolved on PTX10003, PTX10008: All versions prior to 20.4R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1. | ||||
CVE-2020-1650 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-16 | 7.5 High |
On Juniper Networks Junos MX Series with service card configured, receipt of a stream of specific packets may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending these specific packets, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a prolonged Denial of Service. This issue affects MX Series devices using MS-PIC, MS-MIC or MS-MPC service cards with any service configured. This issue affects Juniper Networks Junos OS on MX Series: 17.2R2-S7; 17.3R3-S4, 17.3R3-S5; 17.4R2-S4 and the subsequent SRs (17.4R2-S5, 17.4R2-S6, etc.); 17.4R3; 18.1R3-S3, 18.1R3-S4, 18.1R3-S5, 18.1R3-S6, 18.1R3-S7, 18.1R3-S8; 18.2R3, 18.2R3-S1, 18.2R3-S2; 18.3R2 and the SRs based on 18.3R2; 18.4R2 and the SRs based on 18.4R2; 19.1R1 and the SRs based on 19.1R1; 19.2R1 and the SRs based on 19.2R1; 19.3R1 and the SRs based on 19.3R1. | ||||
CVE-2022-22175 | 1 Juniper | 45 Junos, Mx10, Mx10000 and 42 more | 2024-09-16 | 7.5 High |
An Improper Locking vulnerability in the SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated networked attacker to cause a flowprocessing daemon (flowd) crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can occur in a scenario where the SIP ALG is enabled and specific SIP messages are being processed simultaneously. This issue affects: Juniper Networks Junos OS on MX Series and SRX Series 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1. | ||||
CVE-2021-0251 | 1 Juniper | 17 Junos, Mx10, Mx10003 and 14 more | 2024-09-16 | 8.6 High |
A NULL Pointer Dereference vulnerability in the Captive Portal Content Delivery (CPCD) services daemon (cpcd) of Juniper Networks Junos OS on MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC allows an attacker to send malformed HTTP packets to the device thereby causing a Denial of Service (DoS), crashing the Multiservices PIC Management Daemon (mspmand) process thereby denying users the ability to login, while concurrently impacting other mspmand services and traffic through the device. Continued receipt and processing of these malformed packets will create a sustained Denial of Service (DoS) condition. While the Services PIC is restarting, all PIC services will be bypassed until the Services PIC completes its boot process. An attacker sending these malformed HTTP packets to the device who is not part of the Captive Portal experience is not able to exploit this issue. This issue is not applicable to MX RE-based CPCD platforms. This issue affects: Juniper Networks Junos OS on MX Series 17.3 version 17.3R1 and later versions prior to 17.4 versions 17.4R2-S9, 17.4R3-S2; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R3-S3; 18.3 versions prior to 18.3R3-S1; 18.4 versions prior to 18.4R3; 19.1 versions prior to 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3. This issue does not affect: Juniper Networks Junos OS versions prior to 17.3R1. | ||||
CVE-2021-31369 | 1 Juniper | 18 Junos, Mx10, Mx10000 and 15 more | 2024-09-16 | 5.3 Medium |
On MX Series platforms with MS-MPC/MS-MIC, an Allocation of Resources Without Limits or Throttling vulnerability in Juniper Networks Junos OS allows an unauthenticated network attacker to cause a partial Denial of Service (DoS) with a high rate of specific traffic. If a Class of Service (CoS) rule is attached to the service-set and a high rate of specific traffic is processed by this service-set, for some of the other traffic which has services applied and is being processed by this MS-MPC/MS-MIC drops will be observed. Continued receipted of this high rate of specific traffic will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on MX Series with MS-MPC/MS-MIC: All versions prior to 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2. | ||||
CVE-2020-1665 | 1 Juniper | 17 Ex9200, Junos, Mx10 and 14 more | 2024-09-16 | 5.3 Medium |
On Juniper Networks MX Series and EX9200 Series, in a certain condition the IPv6 Distributed Denial of Service (DDoS) protection might not take affect when it reaches the threshold condition. The DDoS protection allows the device to continue to function while it is under DDoS attack, protecting both the Routing Engine (RE) and the Flexible PIC Concentrator (FPC) during the DDoS attack. When this issue occurs, the RE and/or the FPC can become overwhelmed, which could disrupt network protocol operations and/or interrupt traffic. This issue does not affect IPv4 DDoS protection. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX series and EX9200 Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.2 versions prior to 18.2R2-S7, 18.2R3, 18.2R3-S3; 18.2X75 versions prior to 18.2X75-D30; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2. | ||||
CVE-2020-1655 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-16 | 5.3 Medium |
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of large packets requiring fragmentation, generating the following error messages: [LOG: Err] MQSS(0): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[0:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(0): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1838, QID 0 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk length error in stage 5 - Chunk Address: 0x4321f3 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0x0 [LOG: Notice] Error: /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(0), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D65 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S1 on MX Series; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S4, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability. | ||||
CVE-2021-0205 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-09-16 | 5.8 Medium |
When the "Intrusion Detection Service" (IDS) feature is configured on Juniper Networks MX series with a dynamic firewall filter using IPv6 source or destination prefix, it may incorrectly match the prefix as /32, causing the filter to block unexpected traffic. This issue affects only IPv6 prefixes when used as source and destination. This issue affects MX Series devices using MS-MPC, MS-MIC or MS-SPC3 service cards with IDS service configured. This issue affects: Juniper Networks Junos OS 17.3 versions prior to 17.3R3-S10 on MX Series; 17.4 versions prior to 17.4R3-S3 on MX Series; 18.1 versions prior to 18.1R3-S11 on MX Series; 18.2 versions prior to 18.2R3-S6 on MX Series; 18.3 versions prior to 18.3R3-S4 on MX Series; 18.4 versions prior to 18.4R3-S6 on MX Series; 19.1 versions prior to 19.1R2-S2, 19.1R3-S3 on MX Series; 19.2 versions prior to 19.2R3-S1 on MX Series; 19.3 versions prior to 19.3R2-S5, 19.3R3-S1 on MX Series; 19.4 versions prior to 19.4R3 on MX Series; 20.1 versions prior to 20.1R2 on MX Series; 20.2 versions prior to 20.2R2 on MX Series; | ||||
CVE-2022-22236 | 1 Juniper | 46 Junos, Mx10, Mx10000 and 43 more | 2024-09-16 | 7.5 High |
An Access of Uninitialized Pointer vulnerability in SIP Application Layer Gateway (ALG) of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). When specific valid SIP packets are received the PFE will crash and restart. This issue affects Juniper Networks Junos OS on SRX Series and MX Series: 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S2; 21.2 versions prior to 21.2R3-S2; 21.3 versions prior to 21.3R2-S2, 21.3R3; 21.4 versions prior to 21.4R1-S2, 21.4R2; 22.1 versions prior to 22.1R1-S1, 22.1R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1. | ||||
CVE-2022-22210 | 1 Juniper | 30 Junos, Mx10, Mx10000 and 27 more | 2024-09-16 | 6.5 Medium |
A NULL Pointer Dereference vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX5000 Series and MX Series allows an unauthenticated adjacent attacker to cause a Denial of Service (DoS). On QFX5K Series and MX Series, when the PFE receives a specific VxLAN packet the Layer 2 Address Learning Manager (L2ALM) process will crash leading to an FPC reboot. Continued receipt of this specific packet will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS on QFX5000 Series, MX Series: 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2; 21.2 versions prior to 21.2R2-S1. This issue does not affect Juniper Networks Junos OS: All versions prior to 20.3R1; 21.1 version 21.1R1 and later versions. |