CVE-2018-0018 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2024-09-17 N/A
On SRX Series devices during compilation of IDP policies, an attacker sending specially crafted packets may be able to bypass firewall rules, leading to information disclosure which an attacker may use to gain control of the target device or other internal devices, systems or services protected by the SRX Series device. This issue only applies to devices where IDP policies are applied to one or more rules. Customers not using IDP policies are not affected. Depending on if the IDP updates are automatic or not, as well as the interval between available updates, an attacker may have more or less success in performing reconnaissance or bypass attacks on the victim SRX Series device or protected devices. ScreenOS with IDP is not vulnerable to this issue. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX; 12.3X48 versions prior to 12.3X48-D35 on SRX; 15.1X49 versions prior to 15.1X49-D60 on SRX.
CVE-2021-0206 1 Juniper 17 Junos, Nfx150, Nfx250 and 14 more 2024-09-17 7.5 High
A NULL Pointer Dereference vulnerability in Juniper Networks Junos OS allows an attacker to send a specific packet causing the packet forwarding engine (PFE) to crash and restart, resulting in a Denial of Service (DoS). By continuously sending these specific packets, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue only affects Juniper Networks NFX Series, SRX Series platforms when SSL Proxy is configured. This issue affects Juniper Networks Junos OS on NFX Series and SRX Series: 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S1; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S2, 19.2R2; 19.3 versions prior to 19.3R2. This issue does not affect Juniper Networks Junos OS versions on NFX Series and SRX Series prior to 18.3R1.
CVE-2019-0033 1 Juniper 14 Junos, Srx100, Srx110 and 11 more 2024-09-17 N/A
A firewall bypass vulnerability in the proxy ARP service of Juniper Networks Junos OS allows an attacker to cause a high CPU condition leading to a Denial of Service (DoS). This issue affects only IPv4. Affected releases are Juniper Networks Junos OS: 12.1X46 versions above and including 12.1X46-D25 prior to 12.1X46-D71, 12.1X46-D73 on SRX Series; 12.3X48 versions prior to 12.3X48-D50 on SRX Series; 15.1X49 versions prior to 15.1X49-D75 on SRX Series.
CVE-2022-22178 1 Juniper 45 Junos, Mx10, Mx10000 and 42 more 2024-09-17 7.5 High
A Stack-based Buffer Overflow vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on MX Series and SRX series allows an unauthenticated networked attacker to cause a flowd crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can be triggered by a specific Session Initiation Protocol (SIP) invite packet if the SIP ALG is enabled. Due to this, the PIC will be rebooted and all traffic that traverses the PIC will be dropped. This issue affects: Juniper Networks Junos OS 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2; 21.3 versions prior to 21.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1.
CVE-2018-0049 1 Juniper 58 Ex2200, Ex2200-vc, Ex2300 and 55 more 2024-09-17 7.5 High
A NULL Pointer Dereference vulnerability in Juniper Networks Junos OS allows an attacker to cause the Junos OS kernel to crash. Continued receipt of this specifically crafted malicious MPLS packet will cause a sustained Denial of Service condition. This issue require it to be received on an interface configured to receive this type of traffic. Affected releases are Juniper Networks Junos OS: 12.1X46 versions above and including 12.1X46-D76 prior to 12.1X46-D81 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 12.3R12-S10; 12.3X48 versions above and including 12.3X48-D66 prior to 12.3X48-D75 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions above and including 14.1X53-D115 prior to 14.1X53-D130 on QFabric System; 15.1 versions above and including 15.1F6-S10; 15.1R4-S9; 15.1R6-S6; 15.1 versions above and including 15.1R7 prior to 15.1R7-S2; 15.1X49 versions above and including 15.1X49-D131 prior to 15.1X49-D150 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 15.1X53 versions above 15.1X53-D233 prior to 15.1X53-D235 on QFX5200/QFX5110; 15.1X53 versions up to and including 15.1X53-D471 prior to 15.1X53-D590 on NFX150, NFX250; 15.1X53-D67 on QFX10000 Series; 15.1X53-D59 on EX2300/EX3400; 16.1 versions above and including 16.1R3-S8; 16.1 versions above and including 16.1R4-S9 prior to 16.1R4-S12; 16.1 versions above and including 16.1R5-S4; 16.1 versions above and including 16.1R6-S3 prior to 16.1R6-S6; 16.1 versions above and including 16.1R7 prior to 16.1R7-S2; 16.2 versions above and including 16.2R1-S6; 16.2 versions above and including 16.2R2-S5 prior to 16.2R2-S7; 17.1R1-S7; 17.1 versions above and including 17.1R2-S7 prior to 17.1R2-S9; 17.2R1-S6; 17.2 versions above and including 17.2R2-S4 prior to 17.2R2-S6; 17.2X75 versions above and including 17.2X75-D100 prior to X17.2X75-D101, 17.2X75-D110; 17.3 versions above and including 17.3R1-S4 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.3 versions above and including 17.3R2-S2 prior to 17.3R2-S4 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.3R3 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.4 versions above and including 17.4R1-S3 prior to 17.4R1-S5 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.4R2 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.1 versions above and including 18.1R2 prior to 18.1R2-S3, 18.1R3 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.2 versions above and including 18.2R1 prior to 18.2R1-S2, 18.2R1-S3, 18.2R2 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.2X75 versions above and including 18.2X75-D5 prior to 18.2X75-D20.
CVE-2017-10605 1 Juniper 14 Junos, Srx100, Srx110 and 11 more 2024-09-17 N/A
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
CVE-2019-0043 1 Juniper 47 Acx1000, Acx1100, Acx2000 and 44 more 2024-09-17 7.5 High
In MPLS environments, receipt of a specific SNMP packet may cause the routing protocol daemon (RPD) process to crash and restart. By continuously sending a specially crafted SNMP packet, an attacker can repetitively crash the RPD process causing prolonged denial of service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS : 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D75 on SRX Series; 14.1X53 versions prior to 14.1X53-D48 on EX/QFX series; 15.1 versions prior to 15.1R4-S9, 15.1R7-S2; 15.1F6 versions prior to 15.1F6-S11; 15.1X49 versions prior to 15.1X49-D141, 15.1X49-D144, 15.1X49-D150 on SRX Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 15.1X53 versions prior to 15.1X53-D590 on EX2300/EX3400 Series; 15.1X54 on ACX Series; 16.1 versions prior to 16.1R3-S10, 16.1R4-S11, 16.1R6-S5, 16.1R7; 16.1X65 versions prior to 16.1X65-D48; 16.2 versions prior to 16.2R2-S6; 17.1 versions prior to 17.1R2-S8, 17.1R3; 17.2 versions prior to 17.2R1-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D92, 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3; 17.4 versions prior to 17.4R1-S4, 17.4R2; 18.1 versions prior to 18.1R1-S1, 18.1R2-S1, 18.1R3; 18.2X75 versions prior to 18.2X75-D10.
CVE-2019-0075 1 Juniper 25 Csrx, Junos, Srx100 and 22 more 2024-09-17 7.5 High
A vulnerability in the srxpfe process on Protocol Independent Multicast (PIM) enabled SRX series devices may lead to crash of the srxpfe process and an FPC reboot while processing (PIM) messages. Sustained receipt of these packets may lead to an extended denial of service condition. Affected releases are Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D80; 15.1X49 versions prior to 15.1X49-D160; 17.3 versions prior to 17.3R3-S7 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R2.
CVE-2021-0275 1 Juniper 24 Ex2300, Ex2300-c, Ex3400 and 21 more 2024-09-17 8.8 High
A Cross-site Scripting (XSS) vulnerability in J-Web on Juniper Networks Junos OS allows an attacker to target another user's session thereby gaining access to the users session. The other user session must be active for the attack to succeed. Once successful, the attacker has the same privileges as the user. If the user has root privileges, the attacker may be able to gain full control of the device. This issue affects: Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15 on EX Series; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 15.1 versions prior to 15.1R7-S6 on EX Series; 15.1X49 versions prior to 15.1X49-D200 on SRX Series; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11, 16.2R3; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3; 19.1 versions prior to 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2.
CVE-2019-0054 1 Juniper 25 Csrx, Junos, Srx100 and 22 more 2024-09-17 6.8 Medium
An Improper Certificate Validation weakness in the SRX Series Application Identification (app-id) signature update client of Juniper Networks Junos OS allows an attacker to perform Man-in-the-Middle (MitM) attacks which may compromise the integrity and confidentiality of the device. This issue affects: Juniper Networks Junos OS 15.1X49 versions prior to 15.1X49-D120 on SRX Series devices. No other versions of Junos OS are affected.
CVE-2022-22221 1 Juniper 86 Ex2200, Ex2200-c, Ex2200-vc and 83 more 2024-09-17 7.8 High
An Improper Neutralization of Special Elements vulnerability in the download manager of Juniper Networks Junos OS on SRX Series and EX Series allows a locally authenticated attacker with low privileges to take full control over the device. One aspect of this vulnerability is that the attacker needs to be able to execute any of the "request ..." or "show system download ..." commands. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: All versions prior to 19.2R1-S9, 19.2R3-S5; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2, 20.4R3-S3; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R2-S2, 21.2R3; 21.3 versions prior to 21.3R2, 21.3R3; 21.4 versions prior to 21.4R1-S1, 21.4R2.
CVE-2021-0246 1 Juniper 8 Junos, Srx1500, Srx4100 and 5 more 2024-09-17 7.3 High
On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, devices using tenant services on Juniper Networks Junos OS, due to incorrect default permissions assigned to tenant system administrators a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant. This issue affects: Juniper Networks Junos OS 18.3 version 18.3R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.3 versions prior to 18.3R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.4 versions prior to 18.4R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.1 versions prior to 19.1R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3. This issue does not affect: Juniper Networks Junos OS versions prior to 18.3R1.
CVE-2017-3145 5 Debian, Isc, Juniper and 2 more 43 Debian Linux, Bind, Junos and 40 more 2024-09-17 7.5 High
BIND was improperly sequencing cleanup operations on upstream recursion fetch contexts, leading in some cases to a use-after-free error that can trigger an assertion failure and crash in named. Affects BIND 9.0.0 to 9.8.x, 9.9.0 to 9.9.11, 9.10.0 to 9.10.6, 9.11.0 to 9.11.2, 9.9.3-S1 to 9.9.11-S1, 9.10.5-S1 to 9.10.6-S1, 9.12.0a1 to 9.12.0rc1.
CVE-2019-0003 1 Juniper 35 Ex2200\/vc, Ex2300, Ex3200 and 32 more 2024-09-17 5.9 Medium
When a specific BGP flowspec configuration is enabled and upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, a reachable assertion failure occurs, causing the routing protocol daemon (rpd) process to crash with a core file being generated. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 15.1 versions prior to 15.1R3; 15.1F versions prior to 15.1F3; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400.
CVE-2022-22231 1 Juniper 9 Junos, Srx1500, Srx4100 and 6 more 2024-09-17 7.5 High
An Unchecked Return Value to NULL Pointer Dereference vulnerability in Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). On SRX Series if Unified Threat Management (UTM) Enhanced Content Filtering (CF) and AntiVirus (AV) are enabled together and the system processes specific valid transit traffic the Packet Forwarding Engine (PFE) will crash and restart. This issue affects Juniper Networks Junos OS 21.4 versions prior to 21.4R1-S2, 21.4R2 on SRX Series. This issue does not affect Juniper Networks Junos OS versions prior to 21.4R1.
CVE-2018-0034 1 Juniper 56 Ex2200, Ex2200-c, Ex2200-vc and 53 more 2024-09-16 N/A
A Denial of Service vulnerability exists in the Juniper Networks Junos OS JDHCPD daemon which allows an attacker to core the JDHCPD daemon by sending a crafted IPv6 packet to the system. This issue is limited to systems which receives IPv6 DHCP packets on a system configured for DHCP processing using the JDHCPD daemon. This issue does not affect IPv4 DHCP packet processing. Affected releases are Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S10 on EX Series; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions prior to 14.1X53-D130 on QFabric; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5110, QFX5200; 15.1X53 versions prior to 15.1X53-D471 on NFX 150, NFX 250; 16.1 versions prior to 16.1R3-S9, 16.1R4-S8, 16.1R5-S4, 16.1R6-S3, 16.1R7; 16.2 versions prior to 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.3 versions prior to 17.3R1-S4, 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2.
CVE-2018-0002 1 Juniper 31 Junos, Mx10, Mx104 and 28 more 2024-09-16 N/A
On SRX Series and MX Series devices with a Service PIC with any ALG enabled, a crafted TCP/IP response packet processed through the device results in memory corruption leading to a flowd daemon crash. Sustained crafted response packets lead to repeated crashes of the flowd daemon which results in an extended Denial of Service condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX series; 12.3X48 versions prior to 12.3X48-D35 on SRX series; 14.1 versions prior to 14.1R9 on MX series; 14.2 versions prior to 14.2R8 on MX series; 15.1X49 versions prior to 15.1X49-D60 on SRX series; 15.1 versions prior to 15.1R5-S8, 15.1F6-S9, 15.1R6-S4, 15.1R7 on MX series; 16.1 versions prior to 16.1R6 on MX series; 16.2 versions prior to 16.2R3 on MX series; 17.1 versions prior to 17.1R2-S4, 17.1R3 on MX series. No other Juniper Networks products or platforms are affected by this issue.
CVE-2019-0044 1 Juniper 4 Junos, Srx5400, Srx5600 and 1 more 2024-09-16 7.5 High
Receipt of a specific packet on the out-of-band management interface fxp0 may cause the system to crash and restart (vmcore). By continuously sending a specially crafted packet to the fxp0 interface, an attacker can repetitively crash the rpd process causing prolonged Denial of Service (DoS). Affected releases are Juniper Networks SRX5000 Series: 12.1X46 versions prior to 12.1X46-D82; 12.3X48 versions prior to 12.3X48-D80; 15.1X49 versions prior to 15.1X49-D160.
CVE-2022-22167 1 Juniper 28 Junos, Srx100, Srx110 and 25 more 2024-09-16 7.2 High
A traffic classification vulnerability in Juniper Networks Junos OS on the SRX Series Services Gateways may allow an attacker to bypass Juniper Deep Packet Inspection (JDPI) rules and access unauthorized networks or resources, when 'no-syn-check' is enabled on the device. While JDPI correctly classifies out-of-state asymmetric TCP flows as the dynamic-application UNKNOWN, this classification is not provided to the policy module properly and hence traffic continues to use the pre-id-default-policy, which is more permissive, causing the firewall to allow traffic to be forwarded that should have been denied. This issue only occurs when 'set security flow tcp-session no-syn-check' is configured on the device. This issue affects Juniper Networks Junos OS on SRX Series: 18.4 versions prior to 18.4R2-S10, 18.4R3-S10; 19.1 versions prior to 19.1R3-S8; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 18.4R1.
CVE-2017-10608 1 Juniper 13 Junos, Srx110, Srx1400 and 10 more 2024-09-16 N/A
Any Juniper Networks SRX series device with one or more ALGs enabled may experience a flowd crash when traffic is processed by the Sun/MS-RPC ALGs. This vulnerability in the Sun/MS-RPC ALG services component of Junos OS allows an attacker to cause a repeated denial of service against the target. Repeated traffic in a cluster may cause repeated flip-flop failure operations or full failure to the flowd daemon halting traffic on all nodes. Only IPv6 traffic is affected by this issue. IPv4 traffic is unaffected. This issues is not seen with to-host traffic. This issue has no relation with HA services themselves, only the ALG service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55 on SRX; 12.1X47 prior to 12.1X47-D45 on SRX; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35 on SRX; 15.1X49 prior to 15.1X49-D60 on SRX.