Total
339 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-6145 | 1 Actiontec | 2 Wcb6200q, Wcb6200q Firmware | 2024-09-19 | 8.8 High |
Actiontec WCB6200Q Cookie Format String Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Actiontec WCB6200Q routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HTTP server. A crafted Cookie header in an HTTP request can trigger the use of a format specifier from a user-supplied string. An attacker can leverage this vulnerability to execute code in the context of the HTTP server. Was ZDI-CAN-21417. | ||||
CVE-2024-4641 | 1 Moxa | 8 Oncell G3470a-lte-eu, Oncell G3470a-lte-eu-t, Oncell G3470a-lte-eu-t Firmware and 5 more | 2024-09-18 | 6.3 Medium |
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service. | ||||
CVE-2009-4014 | 1 Debian | 1 Lintian | 2024-09-17 | N/A |
Multiple format string vulnerabilities in Lintian 1.23.x through 1.23.28, 1.24.x through 1.24.2.1, and 2.x before 2.3.2 allow remote attackers to have an unspecified impact via vectors involving (1) check scripts and (2) the Lintian::Schedule module. | ||||
CVE-2022-35875 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2024-09-17 | 9.8 Critical |
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk` configuration parameter, as used within the `testWifiAP` XCMD handler | ||||
CVE-2020-1992 | 1 Paloaltonetworks | 3 Pa-7050, Pa-7080, Pan-os | 2024-09-17 | 8.1 High |
A format string vulnerability in the Varrcvr daemon of PAN-OS on PA-7000 Series devices with a Log Forwarding Card (LFC) allows remote attackers to crash the daemon creating a denial of service condition or potentially execute code with root privileges. This issue affects Palo Alto Networks PAN-OS 9.0 versions before 9.0.7; PAN-OS 9.1 versions before 9.1.2 on PA-7000 Series devices with an LFC installed and configured. This issue requires WildFire services to be configured and enabled. This issue does not affect PAN-OS 8.1 and earlier releases. This issue does not affect any other PA Series firewalls. | ||||
CVE-2007-5561 | 1 Oracle | 2 Enterprise Grid Console Server, Opmn Daemon | 2024-09-17 | N/A |
Format string vulnerability in the logging function in the Oracle OPMN daemon, as used on Oracle Enterprise Grid Console server 10.2.0.1, allows remote attackers to execute arbitrary code via format string specifiers in the URI in an HTTP request to port 6003, aka Oracle reference number 6296175. NOTE: this might be the same issue as CVE-2007-0282 or CVE-2007-0280, but there are insufficient details to be sure. | ||||
CVE-2022-35874 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2024-09-17 | 9.8 Critical |
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler | ||||
CVE-2018-14799 | 1 Philips | 10 Pagewriter Tc10, Pagewriter Tc10 Firmware, Pagewriter Tc20 and 7 more | 2024-09-17 | N/A |
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities. | ||||
CVE-2022-26392 | 1 Baxter | 8 Baxter Spectrum Iq 35700bax3, Baxter Spectrum Iq 35700bax3 Firmware, Sigma Spectrum 35700bax and 5 more | 2024-09-17 | 3.1 Low |
The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information. | ||||
CVE-2017-17132 | 1 Huawei | 2 Vp9660, Vp9660 Firmware | 2024-09-17 | N/A |
Huawei VP9660 V500R002C10 has a uncontrolled format string vulnerability when the license module output the log information. An authenticated local attacker could exploit this vulnerability to cause a denial of service. | ||||
CVE-2018-6508 | 1 Puppet | 1 Puppet Enterprise | 2024-09-17 | N/A |
Puppet Enterprise 2017.3.x prior to 2017.3.3 are vulnerable to a remote execution bug when a specially crafted string was passed into the facter_task or puppet_conf tasks. This vulnerability only affects tasks in the affected modules, if you are not using puppet tasks you are not affected by this vulnerability. | ||||
CVE-2009-4769 | 1 Jasper | 1 Httpdx | 2024-09-17 | N/A |
Multiple format string vulnerabilities in the tolog function in httpdx 1.4, 1.4.5, 1.4.6, 1.4.6b, and 1.5 allow (1) remote attackers to execute arbitrary code via format string specifiers in a GET request to the HTTP server component when logging is enabled, and allow (2) remote authenticated users to execute arbitrary code via format string specifiers in a PWD command to the FTP server component. | ||||
CVE-2011-2475 | 1 Sybase | 1 Onebridge Mobile Data Suite | 2024-09-17 | N/A |
Format string vulnerability in ECTrace.dll in the iMailGateway service in the Internet Mail Gateway in OneBridge Server and DMZ Proxy in Sybase OneBridge Mobile Data Suite 5.5 and 5.6 allows remote attackers to execute arbitrary code via format string specifiers in unspecified string fields, related to authentication logging. | ||||
CVE-2013-5135 | 1 Apple | 2 Apple Remote Desktop, Mac Os X | 2024-09-17 | N/A |
Format string vulnerability in Screen Sharing Server in Apple Mac OS X before 10.9 and Apple Remote Desktop before 3.5.4 allows remote attackers to execute arbitrary code via format string specifiers in a VNC username. | ||||
CVE-2017-0898 | 2 Redhat, Ruby-lang | 3 Enterprise Linux, Rhel Software Collections, Ruby | 2024-09-17 | N/A |
Ruby before 2.4.2, 2.3.5, and 2.2.8 is vulnerable to a malicious format string which contains a precious specifier (*) with a huge minus value. Such situation can lead to a buffer overrun, resulting in a heap memory corruption or an information disclosure from the heap. | ||||
CVE-2021-33535 | 1 Weidmueller | 16 Ie-wl-bl-ap-cl-eu, Ie-wl-bl-ap-cl-eu Firmware, Ie-wl-bl-ap-cl-us and 13 more | 2024-09-17 | 8.8 High |
In Weidmueller Industrial WLAN devices in multiple versions an exploitable format string vulnerability exists in the iw_console conio_writestr functionality. A specially crafted time server entry can cause an overflow of the time server buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability. | ||||
CVE-2022-35244 | 1 Goabode | 2 Iota All-in-one Security Kit, Iota All-in-one Security Kit Firmware | 2024-09-17 | 9.8 Critical |
A format string injection vulnerability exists in the XCMD getVarHA functionality of abode systems, inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to memory corruption, information disclosure, and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability. | ||||
CVE-2022-35877 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2024-09-17 | 9.8 Critical |
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` configuration parameter, as used within the `testWifiAP` XCMD handler | ||||
CVE-2018-1566 | 3 Ibm, Linux, Microsoft | 3 Db2, Linux Kernel, Windows | 2024-09-17 | N/A |
IBM DB2 for Linux, UNIX and Windows (includes DB2 Connect Server) 9.7, 10.1, 10.5, and 11.1 could allow a local user to execute arbitrary code due to a format string error. IBM X-Force ID: 143023. | ||||
CVE-2022-35887 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2024-09-17 | 8.8 High |
Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` HTTP parameter, as used within the `/action/wirelessConnect` handler. |