Search Results (4559 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-48428 1 Gallagher 1 Command Centre 2026-04-15 6.7 Medium
Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior.
CVE-2025-24008 2026-04-15 6.5 Medium
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.
CVE-2025-4378 2026-04-15 10 Critical
Cleartext Transmission of Sensitive Information, Use of Hard-coded Credentials vulnerability in Ataturk University ATA-AOF Mobile Application allows Authentication Abuse, Authentication Bypass.This issue affects ATA-AOF Mobile Application: before 20.06.2025.
CVE-2025-6180 1 Strongdm 1 Sdm-cli 2026-04-15 N/A
The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition.
CVE-2025-2182 1 Palo Alto Networks 1 Pan-os 2026-04-15 N/A
A problem with the implementation of the MACsec protocol in Palo Alto Networks PAN-OS® results in the cleartext exposure of the connectivity association key (CAK). This issue is only applicable to PA-7500 Series devices which are in an NGFW cluster. A user who possesses this key can read messages being sent between devices in a NGFW Cluster. There is no impact in non-clustered firewalls or clusters of firewalls that do not enable MACsec.
CVE-2025-61738 1 Johnsoncontrols 5 Iq Panels2, Iq Panels2+, Iqhub and 2 more 2026-04-15 N/A
Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network.
CVE-2025-52586 1 Eg4 Electronics 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more 2026-04-15 6.9 Medium
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CVE-2025-8863 1 Yugabyte 1 Yugabytedb 2026-04-15 3.7 Low
YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission
CVE-2025-53103 2026-04-15 5.8 Medium
JUnit is a testing framework for Java and the JVM. From version 5.12.0 to 5.13.1, JUnit's support for writing Open Test Reporting XML files can leak Git credentials. The impact depends on the level of the access token exposed through the OpenTestReportGeneratingListener. If these test reports are published or stored anywhere public, then there is the possibility that a rouge attacker can steal the token and perform elevated actions by impersonating the user or app. This issue as been patched in version 5.13.2.
CVE-2025-2181 1 Paloaltonetworks 1 Checkov 2026-04-15 N/A
A sensitive information disclosure vulnerability in Palo Alto Networks Checkov by Prisma® Cloud can result in the cleartext exposure of Prisma Cloud access keys in Checkov's output.
CVE-2025-46820 2026-04-15 7.1 High
phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue.
CVE-2025-10464 1 Birtech Information Technologies Industry And Trade 1 Senseway 2026-04-15 6.5 Medium
Insecure Storage of Sensitive Information vulnerability in Birtech Information Technologies Industry and Trade Ltd. Co. Senseway allows Retrieve Embedded Sensitive Data.This issue affects Senseway: through 09022026. NOTE: Because the product was developed using outdated technology, the manufacturer is unable to fix the relevant vulnerabilities. Users of the Sensaway application are advised to contact the manufacturer and review updated products developed with newer technology.
CVE-2025-4618 2 Palo Alto Networks, Paloaltonetworks 2 Prisma Browser, Prisma Browser 2026-04-15 N/A
A sensitive information disclosure vulnerability in Palo Alto Networks Prisma® Browser allows a locally authenticated non-admin user to retrieve sensitive data from Prisma Browser. Browser self-protection should be enabled to mitigate this issue.
CVE-2025-42888 2 Microsoft, Sap 4 Windows, Gui, Gui For Windows and 1 more 2026-04-15 5.5 Medium
SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability.
CVE-2024-52284 1 Suse 1 Rancher 2026-04-15 7.7 High
Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets.
CVE-2024-5731 2026-04-15 6.8 Medium
A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information.
CVE-2024-23942 2026-04-15 7.1 High
A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS.
CVE-2024-51175 2026-04-15 7.5 High
An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component.
CVE-2024-9991 1 Signify Innovations India 7 Phillips Smart Bulb 10-watt Firmware, Phillips Smart Bulb 12-watt Firmware, Phillips Smart Bulb 9-watt Firmware and 4 more 2026-04-15 N/A
This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected.
CVE-2024-8059 2026-04-15 4.3 Medium
IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters.