| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to hard-coded Root Access Credentials in system configuration of the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to obtain the stored root access credentials.
Successful exploitation of this vulnerability could allow the attacker to gain admin access to the targeted device. |
| Sangoma FreePBX 1805 through 2203 on Linux contains hardcoded credentials for the Asterisk REST Interface (ARI), which allows remote attackers to reconfigure Asterisk and make external and internal calls via HTTP and WebSocket requests sent to the API. |
| NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05. |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device. |
| A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |
| The default password for the extended admin user mode in the application U9ExosAdmin.exe ("Kaba 9300 Administration") is hard-coded in multiple locations as well as documented in the locally stored user documentation. |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host. |