A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of affected products, if configured to allow the import of PKCS12 containers, could end up in an infinite loop when processing incomplete certificate chains. This could allow an authenticated remote attacker to create a denial of service condition by importing specially crafted PKCS12 containers.
Search vulnerabilities
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
A vulnerability has been identified in Mendix RichText (All versions >= V4.0.0 < V4.6.1). Affected widget does not properly neutralize the input. This could allow an attacker to execute cross-site scripting attacks.
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application.
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to cross-site request forgery (CSRF). This could allow an attacker to read or modify the device configuration by tricking an authenticated legitimate user into accessing a malicious link.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files.
A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.
Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services.
Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system. A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.
A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.