| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| Imaster's MEMS Events CRM contains an SQL injection vulnerability in ‘phone’ parameter in ‘/memsdemo/login.php’. |
| SQL injection vulnerability in the DRED virtual campus platform. This vulnerability allows an attacker to retrieve, create, update, and delete data from the database by sending a POST request using the ‘buscame’ parameter in ‘/catalogo_c/catalogo.php’. |
| Incorrect authentication vulnerability in OpenSIAC, which could allow an attacker to impersonate a person using Cl@ve as an authentication method. |
| Prebid Universal Creative (PUC) is a JavaScript API to render multiple formats. Npm users of PUC 1.17.3 or PUC latest were briefly affected by crypto-related malware. This includes the extremely popular jsdelivr hosting of this file. The maintainers of PUC unpublished version 1.17.3. Users should see Prebid.js 9 release notes for suggestions on moving off the deprecated workflow of using the PUC or pointing to a dynamic version of it. PUC users pointing to latest should transition to 1.17.2 as soon as possible to avoid similar attacks in the future. |
| DIAView (v4.2.0 and prior) - Directory Traversal Information Disclosure Vulnerability |
| The CS5000 Fire Panel is vulnerable due to a default account that exists
on the panel. Even though it is possible to change this by SSHing into
the device, it has remained unchanged on every installed system
observed. This account is not root but holds high-level permissions that
could severely impact the device's operation if exploited. |
| SQL injection vulnerability in Infoticketing. This vulnerability allows
an unauthenticated attacker to retrieve, create, update, and delete the
database by sending a POST request using the 'code' parameter in '/components/cart/cartApplyDiscount.php'. |
| Path Traversal vulnerability in WF Steuerungstechnik GmbH airleader MASTER allows Retrieve Embedded Sensitive Data.This issue affects airleader MASTER: 3.0046. |
| SQL injection vulnerability in AES Multimedia's Gestnet v1.07. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘fk_remoto_central’ parameter on the ‘/webservices/articles.php’ endpoint. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to improper authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user. |
| SQL injection vulnerability in Comerzzia Backoffice: Sales Orchestrator 3.0.15. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘uidActivity’, ‘codCompany’ and ‘uidInstance’ parameters of the ‘/comerzzia/login’ endpoint. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| Integer Overflow or Wraparound vulnerability in dragonflydb dragonfly (src/redis/lua/struct modules). This vulnerability is associated with program files lua_struct.C.
This issue affects dragonfly: 1.30.1, 1.30.0, 1.28.18. |