Filtered by vendor Siemens Subscriptions
Total 1848 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2016-5743 1 Siemens 5 Simatic Batch, Simatic Openpcs 7, Simatic Pcs 7 and 2 more 2024-08-06 N/A
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets.
CVE-2016-5744 1 Siemens 1 Simatic Wincc 2024-08-06 N/A
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
CVE-2016-4956 6 Novell, Ntp, Opensuse and 3 more 11 Suse Manager, Ntp, Leap and 8 more 2024-08-06 5.3 Medium
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (interleaved-mode transition and time change) via a spoofed broadcast packet. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-1548.
CVE-2016-4953 5 Ntp, Opensuse, Oracle and 2 more 15 Ntp, Leap, Opensuse and 12 more 2024-08-06 7.5 High
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (ephemeral-association demobilization) by sending a spoofed crypto-NAK packet with incorrect authentication data at a certain time.
CVE-2016-4955 6 Novell, Ntp, Opensuse and 3 more 11 Suse Manager, Ntp, Leap and 8 more 2024-08-06 5.9 Medium
ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service (peer-variable clearing and association outage) by sending (1) a spoofed crypto-NAK packet or (2) a packet with an incorrect MAC value at a certain time.
CVE-2016-4954 5 Ntp, Opensuse, Oracle and 2 more 15 Ntp, Leap, Opensuse and 12 more 2024-08-06 7.5 High
The process_packet function in ntp_proto.c in ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (peer-variable modification) by sending spoofed packets from many source IP addresses in a certain scenario, as demonstrated by triggering an incorrect leap indication.
CVE-2016-3949 1 Siemens 4 Simatic S7-300 With Profitnet Support, Simatic S7-300 With Profitnet Support Firmware, Simatic S7-300 Without Profitnet Support and 1 more 2024-08-06 N/A
Siemens SIMATIC S7-300 Profinet-enabled CPU devices with firmware before 3.2.12 and SIMATIC S7-300 Profinet-disabled CPU devices with firmware before 3.3.12 allow remote attackers to cause a denial of service (defect-mode transition) via crafted (1) ISO-TSAP or (2) Profibus packets.
CVE-2016-3963 1 Siemens 1 Scalance S613 2024-08-06 N/A
Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.
CVE-2016-3155 1 Siemens 1 Apogee Insight 2024-08-05 N/A
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors.
CVE-2016-2846 1 Siemens 2 Simatic S7 1200 Cpu, Simatic S7 Cpu 1200 Firmware 2024-08-05 N/A
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors.
CVE-2016-2518 7 Debian, Freebsd, Netapp and 4 more 20 Debian Linux, Freebsd, Clustered Data Ontap and 17 more 2024-08-05 5.3 Medium
The MATCH_ASSOC function in NTP before version 4.2.8p9 and 4.3.x before 4.3.92 allows remote attackers to cause an out-of-bounds reference via an addpeer request with a large hmode value.
CVE-2016-2200 1 Siemens 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more 2024-08-05 N/A
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102.
CVE-2016-2201 1 Siemens 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more 2024-08-05 N/A
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
CVE-2016-2031 2 Arubanetworks, Siemens 5 Airwave, Aruba Instant, Arubaos and 2 more 2024-08-05 9.8 Critical
Multiple vulnerabilities exists in Aruba Instate before 4.1.3.0 and 4.2.3.1 due to insufficient validation of user-supplied input and insufficient checking of parameters, which could allow a malicious user to bypass security restrictions, obtain sensitive information, perform unauthorized actions and execute arbitrary code.
CVE-2016-1488 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2024-08-05 N/A
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2017-18922 6 Canonical, Fedoraproject, Libvncserver Project and 3 more 19 Ubuntu Linux, Fedora, Libvncserver and 16 more 2024-08-05 9.8 Critical
It was discovered that websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow.
CVE-2017-14491 13 Arista, Arubanetworks, Canonical and 10 more 35 Eos, Arubaos, Ubuntu Linux and 32 more 2024-08-05 9.8 Critical
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.
CVE-2017-14023 1 Siemens 2 Simatic Pcs7, Simatic Wincc 2024-08-05 4.9 Medium
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface.
CVE-2017-12741 1 Siemens 76 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200p and 73 more 2024-08-05 7.5 High
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
CVE-2017-12734 1 Siemens 2 Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware 2024-08-05 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.