| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability, which was classified as problematic, has been found in Abstrium Pydio Cells 4.2.0. This issue affects some unknown processing of the component Chat. The manipulation leads to basic cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 4.2.1 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-230213 was assigned to this vulnerability. |
| Reflected XSS in business intelligence in Checkmk <2.2.0p8, <2.1.0p32, <2.0.0p38, <=1.6.0p30. |
| A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface.
This vulnerability is due to insufficient validation of user input. An attacker could exploit this vulnerability by persuading a user of an affected interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the browser of the targeted user or access sensitive, browser-based information. |
| A vulnerability in the web-based management interface of Cisco Prime Infrastructure and Cisco Evolved Programmable Network Manager (EPNM) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface on an affected device.
The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected system. An attacker could exploit this vulnerability by injecting malicious code into specific pages of the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. |
| A vulnerability in web-based management interface of Cisco SPA500 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to to modify a web page in the context of a user's browser.
This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to alter the contents of a web page to redirect the user to potentially malicious websites, or the attacker could use this vulnerability to conduct further client-side attacks.
Cisco will not release software updates that address this vulnerability.
{{value}} ["%7b%7bvalue%7d%7d"])}]] |
| A vulnerability in the web-based management interface of Cisco Small Business SPA500 Series IP Phones could allow an unauthenticated, remote attacker to conduct XSS attacks. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. |
| A vulnerability in the web-based management interface of Cisco Catalyst SD-WAN Manager, formerly Cisco SD-WAN vManage, could allow an authenticated, remote attacker to inject HTML content.
This vulnerability is due to improper validation of user-supplied data in element fields. An attacker could exploit this vulnerability by submitting malicious content within requests and persuading a user to view a page that contains injected content. A successful exploit could allow the attacker to modify pages within the web-based management interface, possibly leading to further browser-based attacks against users of the application. |
| A vulnerability in the bidirectional forwarding detection (BFD) hardware offload feature of Cisco IOS XR Software for Cisco ASR 9000 Series Aggregation Services Routers, ASR 9902 Compact High-Performance Routers, and ASR 9903 Compact High-Performance Routers could allow an unauthenticated, remote attacker to cause a line card to reset, resulting in a denial of service (DoS) condition. This vulnerability is due to the incorrect handling of malformed BFD packets that are received on line cards where the BFD hardware offload feature is enabled. An attacker could exploit this vulnerability by sending a crafted IPv4 BFD packet to an affected device. A successful exploit could allow the attacker to cause line card exceptions or a hard reset, resulting in loss of traffic over that line card while the line card reloads. |
| A vulnerability has been identified in SIMATICÂ PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.
This could allow an attacker to create a buffer overflow and create a denial of service condition for the device. |
| A vulnerability, which was classified as problematic, was found in Webmin 2.001. Affected is an unknown function of the file xterm/index.cgi. The manipulation leads to basic cross site scripting. It is possible to launch the attack remotely. Upgrading to version 2.003 is able to address this issue. The patch is identified as d3d33af3c0c3fd3a889c84e287a038b7a457d811. It is recommended to upgrade the affected component. VDB-212862 is the identifier assigned to this vulnerability. |
| Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in gVectors Team wpForo Forum allows Content Spoofing.This issue affects wpForo Forum: from n/a through 2.0.9. |
| An improper neutralization of script-related HTML tags in a web page vulnerability [CWE-80] in FortiAuthenticator versions 6.4.0 through 6.4.4, 6.3.0 through 6.3.3, all versions of 6.2 and 6.1 may allow a remote unauthenticated attacker to trigger a reflected cross site scripting (XSS) attack via the "reset-password" page. |
| In Apache ActiveMQ Artemis prior to 2.24.0, an attacker could show malicious content and/or redirect users to a malicious URL in the web console by using HTML in the name of an address or queue. |
| In JetBrains YouTrack before 2022.1.43563 HTML code from the issue description was being rendered |
| A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. |
| Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in Group Functionality of Profelis IT Consultancy SambaBox allows AUTHENTICATED user to cause execute arbitrary codes on the vulnerable server. This issue affects: Profelis IT Consultancy SambaBox 4.0 version 4.0 and prior versions on x86. |
| A flaw in the TETRA authentication procecure allows a MITM adversary that can predict the MS challenge RAND2 to set session key DCK to zero. |
| A vulnerability in the web-based management interface of Cisco IoT Control Center could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. |
| A vulnerability in the web applications of Cisco UCS Director could allow an authenticated, remote attacker to conduct a cross-site scripting attack on an affected system. This vulnerability is due to unsanitized user input. An attacker could exploit this vulnerability by submitting custom JavaScript to affected web applications. A successful exploit could allow the attacker to rewrite web page content, access sensitive information stored in the applications, and alter data by submitting forms. |
| The Very Simple Contact Form WordPress plugin before 11.6 exposes the solution to the captcha in the rendered contact form, both as hidden input fields and as plain text in the page, making it very easy for bots to bypass the captcha check, rendering the page a likely target for spam bots. |