| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The affected product is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities. |
| Omron CX-Position (versions 2.5.3 and prior) is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code. |
| Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code. |
| Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code. |
| An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior. |
| The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. |
| A remote attacker with write access to PI ProcessBook files could inject code that is imported into OSIsoft PI Vision 2020 versions prior to 3.5.0. Unauthorized information disclosure, modification, or deletion is also possible if a victim views or interacts with the infected display. This vulnerability affects PI System data and other data accessible with victim’s user permissions. |
| Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page. |
| ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition. |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to an out-of-bounds write condition, which may result in a system crash or allow an attacker to remotely execute arbitrary code. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| The affected product is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. |
| The affected product is vulnerable to an out-of-bounds write via uninitialized pointer, which may allow an attacker to execute arbitrary code. |
| Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters. |
| A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 may send OS commands to execute on the host server. |
| The main MiCODUS MV720 GPS tracker web server has a reflected cross-site scripting vulnerability that could allow an attacker to gain control by tricking a user into making a request. |
| An authenticated mySCADA myPRO 8.26.0 user may be able to modify parameters to run commands directly in the operating system. |
| Alpha7 PC Loader (All versions) is vulnerable to a stack-based buffer overflow while processing a specifically crafted project file, which may allow an attacker to execute arbitrary code. |