| TeslaMate before 1.25.1 (when using the default Docker configuration) allows attackers to open doors of Tesla vehicles, start Keyless Driving, and interfere with vehicle operation en route. This occurs because an attacker can leverage Grafana login access to obtain a token for Tesla API calls. |
| In TeslaMate before 1.27.2, there is unauthorized access to port 4000 for remote viewing and operation of user data. After accessing the IP address for the TeslaMate instance, an attacker can switch the port to 3000 to enter Grafana for remote operations. At that time, the default username and password can be used to enter the Grafana management console without logging in, a related issue to CVE-2022-23126. |
| auth-js is an isomorphic Javascript library for Supabase Auth. Prior to version 2.69.1, the library functions getUserById, deleteUser, updateUserById, listFactors and deleteFactor did not require the user supplied values to be valid UUIDs. This could lead to a URL path traversal, resulting in the wrong API function being called. Implementations that follow security best practice and validate user controlled inputs, such as the userId are not affected by this. This issue has been patched in version 2.69.1. |
| A vulnerability, which was classified as critical, has been found in Gowabby HFish 0.1. This issue affects the function LoadUrl of the file \view\url.go. The manipulation of the argument r leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |
| IBM Maximo Asset Management 7.6.1.1, 7.6.1.2, and 7.6.1.3 could allow a user to bypass authentication and obtain sensitive information or perform tasks they should not have access to. IBM X-Force ID: 236311. |
| Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated remote attacker to enable telnet access to the router's OS by sending a /goform/telnet web request. |
| Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated remote attacker to enable 'ate' (a remote system management binary) by sending a /goform/ate web request. |
| An issue was discovered in the auth component in Dovecot 2.2 and 2.3 before 2.3.20. When two passdb configuration entries exist with the same driver and args settings, incorrect username_filter and mechanism settings can be applied to passdb definitions. These incorrectly applied settings can lead to an unintended security configuration and can permit privilege escalation in certain configurations. The documentation does not advise against the use of passdb definitions that have the same driver and args settings. One such configuration would be where an administrator wishes to use the same PAM configuration or passwd file for both normal and master users but use the username_filter setting to restrict which of the users is able to be a master user. |
| Medtronic MyCareLink Smart 25000 contains
an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication. |
| Auth0-PHP provides the PHP SDK for Auth0 Authentication and Management APIs. Starting in version 8.0.0-BETA1 and prior to version 8.14.0, session cookies of applications using the Auth0-PHP SDK configured with CookieStore have authentication tags that can be brute forced, which may result in unauthorized access. Certain pre-conditions are required to be vulnerable to this issue: Applications using the Auth0-PHP SDK, or the Auth0/symfony, Auth0/laravel-auth0, and Auth0/wordpress SDKs that rely on the Auth0-PHP SDK; and session storage configured with CookieStore. Upgrade Auth0/Auth0-PHP to v8.14.0 to receive a patch. As an additional precautionary measure, rotating cookie encryption keys is recommended. Note that once updated, any previous session cookies will be rejected. |
| An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Bypassing of Device Pairing can occur. The pairing mechanism relies solely on the connecting device's MAC address. By obtaining the MAC address through network scanning and spoofing it, an attacker can bypass the authentication process and gain full access to the dashcam's features without proper authorization. |
| An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Remotely Dumping of Video Footage and the Live Video Stream can occur. It allows remote attackers to access and download recorded video footage from the SD card via port 9091. Additionally, attackers can connect to port 9092 to stream the live video feed by bypassing the challenge-response authentication mechanism. This exposes sensitive location and personal data. |
| An improper authentication vulnerability exists in Rocket.Chat Mobile App <4.14.1.22788 that allowed an attacker with physical access to a mobile device to bypass local authentication (PIN code). |
| In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator. |
| Medtronic MiniMed Insulin Pumps
are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery. |
| Velneo vClient on its 28.1.3 version, does not correctly check the certificate of authenticity by default. This could allow an attacker that has access to the network to perform a MITM attack in order to obtain the user´s credentials. |
| Medtronic MiniMed MMT
devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery. |
| The OAuth client Single Sign On WordPress plugin before 3.0.4 does not have authorisation and CSRF when updating its settings, which could allow unauthenticated attackers to update them and change the OAuth endpoints to ones they controls, allowing them to then be authenticated as admin if they know the correct email address |
| PAM-PKCS#11 is a Linux-PAM login module that allows a X.509 certificate based user login. Prior to version 0.6.13, if cert_policy is set to none (the default value), then pam_pkcs11 will only check if the user is capable of logging into the token. An attacker may create a different token with the user's public data (e.g. the user's certificate) and a PIN known to the attacker. If no signature with the private key is required, then the attacker may now login as user with that created token. The default to *not* check the private key's signature has been changed with commit commi6638576892b59a99389043c90a1e7dd4d783b921, so that all versions starting with pam_pkcs11-0.6.0 should be affected. As a workaround, in `pam_pkcs11.conf`, set at least `cert_policy = signature;`. |
| A vulnerability has been found in D-Link DHP-W310AV 1.04 and classified as critical. This vulnerability affects unknown code. The manipulation leads to authentication bypass by spoofing. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |