A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP. |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. |
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP. |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP. |
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103) (All Versions) |
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer. |
A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user. |
A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders. |
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file. |
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer. |
Incorrect Default Permission vulnerability exists in SoMove (V2.8.1) and prior which could cause elevation of privilege and provide full access control to local system users to SoMove component and services when a SoMove installer script is launched. |
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used. |
Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal. |
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor. |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories. |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories. |
A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit. |
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account. |
A CWE-20: Improper input validation vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to modify project configuration files. |