| Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
|
| An information disclosure vulnerability exists due to the hardcoded TLS key of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. |
| An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability. |
| An authentication bypass vulnerability exists in the device password generation functionality of Swift Sensors Gateway SG3-1010. A specially-crafted network request can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability. |
| An information disclosure vulnerability exists in the router configuration export functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to increased privileges. An attacker can send an HTTP request to trigger this vulnerability. |
| A hard-coded password vulnerability exists in the console infactory functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted network request can lead to privileged operation execution. An attacker can send a sequence of requests to trigger this vulnerability. |
| A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability. |
| An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability. |
| A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability. |
| A vulnerability was found in Telecommunication Software SAMwin Contact Center Suite 5.1. It has been rated as critical. Affected by this issue is the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the credential handler. Authentication is possible with hard-coded credentials. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component. |
| A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been classified as very critical. This affects an unknown part. The manipulation leads to weak authentication. It is possible to initiate the attack remotely. |
| Victure PC420 1.1.39 was discovered to use a weak encryption key for the file enabled_telnet.dat on the Micro SD card. |
| Victure PC420 1.1.39 was discovered to use a weak and partially hardcoded key to encrypt data. |
| Victure PC420 1.1.39 was discovered to contain a hardcoded root password which is stored in plaintext. |
| Some Dahua software products have a vulnerability of using of hard-coded cryptographic key. An attacker can obtain the AES crypto key by exploiting this vulnerability. |
| Django 1.8.x before 1.8.16, 1.9.x before 1.9.11, and 1.10.x before 1.10.3 use a hardcoded password for a temporary database user created when running tests with an Oracle database, which makes it easier for remote attackers to obtain access to the database server by leveraging failure to manually specify a password in the database settings TEST dictionary. |
| The customization template in Red Hat CloudForms 3.1 Management Engine (CFME) 5.3 uses a default password for the root account when a password is not specified for a new image, which allows remote attackers to gain privileges. |
| The puppet manifests in the Red Hat openstack-puppet-modules package before 2014.2.13-2 uses a default password of CHANGEME for the pcsd daemon, which allows remote attackers to execute arbitrary shell commands via unspecified vectors. |
| NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration. |
| ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session. |