Search Results (81327 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-48592 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the vendor_country parameter of the “vendor print report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48591 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the vendor_state parameter of the “vendor print report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48590 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “admin dynamic app mib errors” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48589 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “reporting job editor” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48588 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “schedule editor decoupled” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48587 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “schedule editor” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48586 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “json walker” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48585 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A SQL injection vulnerability exists in the “admin brand portal” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
CVE-2022-48584 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A command injection vulnerability exists in the download and convert report feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
CVE-2022-48583 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A command injection vulnerability exists in the dashboard scheduler feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
CVE-2022-48582 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A command injection vulnerability exists in the ticket report generate feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
CVE-2022-48581 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A command injection vulnerability exists in the “dash export” feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
CVE-2022-48580 1 Sciencelogic 1 Sl1 2024-11-21 8.8 High
A command injection vulnerability exists in the ARP ping device tool feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
CVE-2022-48579 1 Rarlab 1 Unrar 2024-11-21 7.5 High
UnRAR before 6.2.3 allows extraction of files outside of the destination folder via symlink chains.
CVE-2022-48578 1 Apple 1 Macos 2024-11-21 7.1 High
An out-of-bounds read was addressed with improved bounds checking. This issue is fixed in macOS Monterey 12.5. Processing an AppleScript may result in unexpected termination or disclosure of process memory.
CVE-2022-48571 1 Memcached 1 Memcached 2024-11-21 7.5 High
memcached 1.6.7 allows a Denial of Service via multi-packet uploads in UDP.
CVE-2022-48570 1 Cryptopp 1 Crypto\+\+ 2024-11-21 7.5 High
Crypto++ through 8.4 contains a timing side channel in ECDSA signature generation. Function FixedSizeAllocatorWithCleanup could write to memory outside of the allocation if the allocated memory was not 16-byte aligned. NOTE: this issue exists because the CVE-2019-14318 fix was intentionally removed for functionality reasons.
CVE-2022-48560 3 Debian, Python, Redhat 4 Debian Linux, Python, Enterprise Linux and 1 more 2024-11-21 7.5 High
A use-after-free exists in Python through 3.9 via heappushpop in heapq.
CVE-2022-48520 1 Huawei 2 Emui, Harmonyos 2024-11-21 7.5 High
Unauthorized access vulnerability in the SystemUI module. Successful exploitation of this vulnerability may affect confidentiality.
CVE-2022-48519 1 Huawei 2 Emui, Harmonyos 2024-11-21 7.5 High
Unauthorized access vulnerability in the SystemUI module. Successful exploitation of this vulnerability may affect confidentiality.