| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) |
| A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1) |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior |
| A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior |
| A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior |
| A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior) |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior) |
| A CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over network port 1105/TCP. Affected Product: Modicon M218 Logic Controller (V5.1.0.6 and prior) |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions) |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions) |
| A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior) |
| A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol. |
| A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). |
| A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) |
| A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) |
| A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) |
| A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions) |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. |