Filtered by vendor Schneider-electric
Subscriptions
Total
762 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2018-7772 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be embedded in the HTTP cookie of the request. | ||||
CVE-2018-7771 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A directory traversal vulnerability allows a caller with standard user privileges to write arbitrary php files anywhere in the web service directory tree. | ||||
CVE-2018-7770 | 1 Schneider-electric | 1 U.motion | 2024-11-21 | N/A |
The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | ||||
CVE-2018-7769 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter. | ||||
CVE-2018-7768 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter. | ||||
CVE-2018-7767 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter. | ||||
CVE-2018-7766 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter. | ||||
CVE-2018-7765 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter. | ||||
CVE-2018-7764 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet. | ||||
CVE-2018-7763 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | N/A |
The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The 'css' parameter contains a directory traversal vulnerability. | ||||
CVE-2018-7762 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | N/A |
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | ||||
CVE-2018-7761 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | N/A |
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | ||||
CVE-2018-7760 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | N/A |
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. | ||||
CVE-2018-7759 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | N/A |
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. | ||||
CVE-2018-7758 | 1 Schneider-electric | 46 Micom P141, Micom P141 Firmware, Micom P142 and 43 more | 2024-11-21 | N/A |
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number. | ||||
CVE-2018-7522 | 1 Schneider-electric | 2 Triconex Tricon Mp 3008, Triconex Tricon Mp 3008 Firmware | 2024-11-21 | N/A |
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. | ||||
CVE-2018-7246 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | N/A |
A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext | ||||
CVE-2018-7245 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | N/A |
An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization. | ||||
CVE-2018-7244 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | N/A |
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained. | ||||
CVE-2018-7243 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | N/A |
An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system. |