| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Loading a DLL through an Uncontrolled Search Path Element in the Bosch Monitor Wall installer up to and including version 10.00.0164 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from. |
| Loading a DLL through an Uncontrolled Search Path Element in the Bosch Configuration Manager installer up to and including version 7.21.0078 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from. |
| Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Client installer up to and including version 1.7.6.079 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from. |
| Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from. |
| Loading a DLL through an Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer in versions 10.1.0, 10.0.1, 10.0.0 and 9.0.0 and older potentially allows an attacker to execute arbitrary code on a victim's system. This affects both the installer as well as the installed application. This also affects Bosch DIVAR IP 7000 R2, Bosch DIVAR IP all-in-one 5000 and Bosch DIVAR IP all-in-one 7000 with installers and installed BVMS versions prior to BVMS 10.1.1. |
| A vulnerability in the web-based management interface of Bosch PRAESIDEO until and including version 4.41 and Bosch PRAESENSA until and including version 1.10 allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (Cross-Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or submitting a malicious form. A successful exploit allows the attacker to perform arbitrary actions with the privileges of the victim, e.g. creating and modifying user accounts, changing system configuration settings and cause DoS conditions. Note: For Bosch PRAESIDEO 4.31 and newer and Bosch PRAESENSA in all versions, the confidentiality impact is considered low because user credentials are not shown in the web interface. |
| Loading a DLL through an Uncontrolled Search Path Element in Bosch IP Helper up to and including version 1.00.0008 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same application directory as the portable IP Helper application. |
| A path traversal vulnerability in the Bosch Video Management System (BVMS) NoTouch deployment allows an unauthenticated remote attacker to read arbitrary files from the Central Server. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch BVMS Viewer versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable BVMS version is installed. |
| A path traversal vulnerability in the Bosch Video Management System (BVMS) FileTransferService allows an authenticated remote attacker to read arbitrary files from the Central Server. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch BVMS Viewer versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable BVMS version is installed. |
| D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET. |
| contentHostProperties.php in Rasilient PixelStor 5000 K:4.0.1580-20150629 (KDI Version) allows authenticated attackers to remotely execute code via the name parameter. |
| A DLL Hijacking vulnerability in Eaton's 9000x Programming and Configuration Software v 2.0.38 and prior allows an attacker to execute arbitrary code by replacing the required DLLs with malicious DLLs when the software try to load vci11un6.DLL and cinpl.DLL. |
| Incorrect Privilege Assignment vulnerability in Eaton's Intelligent Power Manager (IPM) v1.67 & prior allow non-admin users to upload the system configuration files by sending specially crafted requests. This can result in non-admin users manipulating the system configurations via uploading the configurations with incorrect parameters. |
| Improper Input Validation in Eaton's Intelligent Power Manager (IPM) v 1.67 & prior on file name during configuration file import functionality allows attackers to perform command injection or code execution via specially crafted file names while uploading the configuration file in the application. |
| UPS companion software v1.05 & Prior is affected by ‘Eval Injection’ vulnerability. The software does not neutralize or incorrectly neutralizes code syntax before using the input in a dynamic evaluation call e.g.”eval” in “Update Manager” class when software attempts to see if there are updates available. This results in arbitrary code execution on the machine where software is installed. |
| An insufficient session expiration vulnerability in FortiDeceptor 3.0.0 and below allows an attacker to reuse the unexpired admin user session IDs to gain admin privileges, should the attacker be able to obtain that session ID via other, hypothetical attacks. |
| Grin through 2.1.1 has Insufficient Validation. |
| Ming (aka libming) 0.4.8 has a heap-based buffer over-read in the function decompile_SWITCH() in decompile.c. |
| jhead through 3.04 has a heap-based buffer over-read in Get32s when called from ProcessGpsInfo in gpsinfo.c. |
| jhead through 3.04 has a heap-based buffer over-read in process_DQT in jpgqguess.c. |