Filtered by vendor Juniper
Subscriptions
Filtered by product Mx2010
Subscriptions
Total
60 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-0205 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 5.8 Medium |
When the "Intrusion Detection Service" (IDS) feature is configured on Juniper Networks MX series with a dynamic firewall filter using IPv6 source or destination prefix, it may incorrectly match the prefix as /32, causing the filter to block unexpected traffic. This issue affects only IPv6 prefixes when used as source and destination. This issue affects MX Series devices using MS-MPC, MS-MIC or MS-SPC3 service cards with IDS service configured. This issue affects: Juniper Networks Junos OS 17.3 versions prior to 17.3R3-S10 on MX Series; 17.4 versions prior to 17.4R3-S3 on MX Series; 18.1 versions prior to 18.1R3-S11 on MX Series; 18.2 versions prior to 18.2R3-S6 on MX Series; 18.3 versions prior to 18.3R3-S4 on MX Series; 18.4 versions prior to 18.4R3-S6 on MX Series; 19.1 versions prior to 19.1R2-S2, 19.1R3-S3 on MX Series; 19.2 versions prior to 19.2R3-S1 on MX Series; 19.3 versions prior to 19.3R2-S5, 19.3R3-S1 on MX Series; 19.4 versions prior to 19.4R3 on MX Series; 20.1 versions prior to 20.1R2 on MX Series; 20.2 versions prior to 20.2R2 on MX Series; | ||||
CVE-2021-0202 | 1 Juniper | 17 Ex9200, Junos, Mx10 and 14 more | 2024-11-21 | 7.5 High |
On Juniper Networks MX Series and EX9200 Series platforms with Trio-based MPC (Modular Port Concentrator) where Integrated Routing and Bridging (IRB) interface is configured and it is mapped to a VPLS instance or a Bridge-Domain, certain network events at Customer Edge (CE) device may cause memory leak in the MPC which can cause an out of memory and MPC restarts. When this issue occurs, there will be temporary traffic interruption until the MPC is restored. An administrator can use the following CLI command to monitor the status of memory usage level of the MPC: user@device> show system resource-monitor fpc FPC Resource Usage Summary Free Heap Mem Watermark : 20 % Free NH Mem Watermark : 20 % Free Filter Mem Watermark : 20 % * - Watermark reached Slot # % Heap Free RTT Average RTT 1 87 PFE # % ENCAP mem Free % NH mem Free % FW mem Free 0 NA 88 99 1 NA 89 99 When the issue is occurring, the value of “% NH mem Free” will go down until the MPC restarts. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3R3-S8; 17.4R3-S2; 18.2R3-S4, 18.2R3-S5; 18.3R3-S2, 18.3R3-S3; 18.4 versions starting from 18.4R3-S1 and later versions prior to 18.4R3-S6; 19.2 versions starting from 19.2R2 and later versions prior to 19.2R3-S1; 19.4 versions starting from 19.4R2 and later versions prior to 19.4R2-S3, 19.4R3; 20.2 versions starting from 20.2R1 and later versions prior to 20.2R1-S3, 20.2R2. This issue does not affect Juniper Networks Junos OS: 18.1, 19.1, 19.3, 20.1. | ||||
CVE-2020-1680 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 5.3 Medium |
On Juniper Networks MX Series with MS-MIC or MS-MPC card configured with NAT64 configuration, receipt of a malformed IPv6 packet may crash the MS-PIC component on MS-MIC or MS-MPC. This issue occurs when a multiservice card is translating the malformed IPv6 packet to IPv4 packet. An unauthenticated attacker can continuously send crafted IPv6 packets through the device causing repetitive MS-PIC process crashes, resulting in an extended Denial of Service condition. This issue affects Juniper Networks Junos OS on MX Series: 15.1 versions prior to 15.1R7-S7; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S11, 17.4R3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D53, 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2. | ||||
CVE-2020-1665 | 1 Juniper | 17 Ex9200, Junos, Mx10 and 14 more | 2024-11-21 | 5.3 Medium |
On Juniper Networks MX Series and EX9200 Series, in a certain condition the IPv6 Distributed Denial of Service (DDoS) protection might not take affect when it reaches the threshold condition. The DDoS protection allows the device to continue to function while it is under DDoS attack, protecting both the Routing Engine (RE) and the Flexible PIC Concentrator (FPC) during the DDoS attack. When this issue occurs, the RE and/or the FPC can become overwhelmed, which could disrupt network protocol operations and/or interrupt traffic. This issue does not affect IPv4 DDoS protection. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX series and EX9200 Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.2 versions prior to 18.2R2-S7, 18.2R3, 18.2R3-S3; 18.2X75 versions prior to 18.2X75-D30; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2. | ||||
CVE-2020-1655 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 5.3 Medium |
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of large packets requiring fragmentation, generating the following error messages: [LOG: Err] MQSS(0): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[0:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(0): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1838, QID 0 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk length error in stage 5 - Chunk Address: 0x4321f3 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0x0 [LOG: Notice] Error: /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(0), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D65 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S1 on MX Series; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S4, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability. | ||||
CVE-2020-1651 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 6.5 Medium |
On Juniper Networks MX series, receipt of a stream of specific Layer 2 frames may cause a memory leak resulting in the packet forwarding engine (PFE) on the line card to crash and restart, causing traffic interruption. By continuously sending this stream of specific layer 2 frame, an attacker connected to the same broadcast domain can repeatedly crash the PFE, causing a prolonged Denial of Service (DoS). This issue affects Juniper Networks Junos OS on MX Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.1 versions prior to 18.1R2. This issue does not affect Juniper Networks Junos OS releases prior to 17.2R1. | ||||
CVE-2020-1650 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 7.5 High |
On Juniper Networks Junos MX Series with service card configured, receipt of a stream of specific packets may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending these specific packets, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a prolonged Denial of Service. This issue affects MX Series devices using MS-PIC, MS-MIC or MS-MPC service cards with any service configured. This issue affects Juniper Networks Junos OS on MX Series: 17.2R2-S7; 17.3R3-S4, 17.3R3-S5; 17.4R2-S4 and the subsequent SRs (17.4R2-S5, 17.4R2-S6, etc.); 17.4R3; 18.1R3-S3, 18.1R3-S4, 18.1R3-S5, 18.1R3-S6, 18.1R3-S7, 18.1R3-S8; 18.2R3, 18.2R3-S1, 18.2R3-S2; 18.3R2 and the SRs based on 18.3R2; 18.4R2 and the SRs based on 18.4R2; 19.1R1 and the SRs based on 19.1R1; 19.2R1 and the SRs based on 19.2R1; 19.3R1 and the SRs based on 19.3R1. | ||||
CVE-2020-1649 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 7.5 High |
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of small fragments requiring reassembly, generating the following error messages: [LOG: Err] MQSS(2): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[2:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(2): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1960, QID 0 [LOG: Err] MQSS(2): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0xc38fb1 [LOG: Notice] Error: /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(2), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D34, 18.2X75-D41, 18.2X75-D53, 18.2X75-D65, 18.2X75-D430 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2 on MX Series; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability. | ||||
CVE-2020-1638 | 1 Juniper | 11 Junos, Junos Os Evolved, Mx10003 and 8 more | 2024-11-21 | 7.5 High |
The FPC (Flexible PIC Concentrator) of Juniper Networks Junos OS and Junos OS Evolved may restart after processing a specific IPv4 packet. Only packets destined to the device itself, successfully reaching the RE through existing edge and control plane filtering, will be able to cause the FPC restart. When this issue occurs, all traffic via the FPC will be dropped. By continuously sending this specific IPv4 packet, an attacker can repeatedly crash the FPC, causing an extended Denial of Service (DoS) condition. This issue can only occur when processing a specific IPv4 packet. IPv6 packets cannot trigger this issue. This issue affects: Juniper Networks Junos OS on MX Series with MPC10E or MPC11E and PTX10001: 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. Juniper Networks Junos OS Evolved on on QFX5220, and PTX10003 series: 19.2-EVO versions; 19.3-EVO versions; 19.4-EVO versions prior to 19.4R2-EVO. This issue does not affect Junos OS versions prior to 19.2R1. This issue does not affect Junos OS Evolved versions prior to 19.2R1-EVO. | ||||
CVE-2020-1633 | 1 Juniper | 16 Junos, Mx10, Mx10000 and 13 more | 2024-11-21 | 7.4 High |
Due to a new NDP proxy feature for EVPN leaf nodes introduced in Junos OS 17.4, crafted NDPv6 packets could transit a Junos device configured as a Broadband Network Gateway (BNG) and reach the EVPN leaf node, causing a stale MAC address entry. This could cause legitimate traffic to be discarded, leading to a Denial of Service (DoS) condition. This issue only affects Junos OS 17.4 and later releases. Prior releases do not support this feature and are unaffected by this vulnerability. This issue only affects IPv6. IPv4 ARP proxy is unaffected by this vulnerability. This issue affects Juniper Networks Junos OS: 17.4 versions prior to 17.4R2-S9, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S9 on MX Series; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3 on MX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S2, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series. | ||||
CVE-2020-1608 | 1 Juniper | 17 Junos, Mx10, Mx10003 and 14 more | 2024-11-21 | 7.5 High |
Receipt of a specific MPLS or IPv6 packet on the core facing interface of an MX Series device configured for Broadband Edge (BBE) service may trigger a kernel crash (vmcore), causing the device to reboot. The issue is specific to the processing of packets destined to BBE clients connected to MX Series subscriber management platforms. This issue affects MX Series running Juniper Networks Junos OS: 17.2 versions starting from17.2R2-S6, 17.2R3 and later releases, prior to 17.2R3-S3; 17.3 versions starting from 17.3R2-S4, 17.3R3-S2 and later releases, prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions starting from 17.4R2 and later releases, prior to 17.4R2-S7,17.4R3; 18.1 versions starting from 18.1R2-S3, 18.1R3 and later releases, prior to 18.1R3-S6; 18.2 versions starting from18.2R1-S1, 18.2R2 and later releases, prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R2-S6. | ||||
CVE-2019-0065 | 1 Juniper | 18 Junos, Mx10, Mx10003 and 15 more | 2024-11-21 | 5.3 Medium |
On MX Series, when the SIP ALG is enabled, receipt of a certain malformed SIP packet may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending a crafted SIP packet, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a sustained Denial of Service. This issue affects Juniper Networks Junos OS on MX Series: 16.1 versions prior to 16.1R7-S5; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R3-S6 ; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S3; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2. | ||||
CVE-2019-0063 | 1 Juniper | 18 Junos, Mx10, Mx10003 and 15 more | 2024-11-21 | 6.5 Medium |
When an MX Series Broadband Remote Access Server (BRAS) is configured as a Broadband Network Gateway (BNG) with DHCPv6 enabled, jdhcpd might crash when receiving a specific crafted DHCP response message on a subscriber interface. The daemon automatically restarts without intervention, but continuous receipt of specific crafted DHCP messages will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue only affects systems configured with DHCPv6 enabled. DHCPv4 is unaffected by this issue. This issue affects Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S5 on MX Series; 16.1 versions prior to 16.1R7-S5 on MX Series; 16.2 versions prior to 16.2R2-S10 on MX Series; 17.1 versions prior to 17.1R3-S1 on MX Series; 17.2 versions prior to 17.2R3-S2 on MX Series; 17.3 versions prior to 17.3R3-S6 on MX Series; 17.4 versions prior to 17.4R2-S5, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S6 on MX Series; 18.2 versions prior to 18.2R2-S4, 18.2R3 on MX Series; 18.2X75 versions prior to 18.2X75-D50 on MX Series; 18.3 versions prior to 18.3R1-S5, 18.3R3 on MX Series; 18.4 versions prior to 18.4R2 on MX Series; 19.1 versions prior to 19.1R1-S2, 19.1R2 on MX Series. | ||||
CVE-2019-0056 | 1 Juniper | 6 Junos, Mx2008, Mx2010 and 3 more | 2024-11-21 | 7.5 High |
This issue only affects devices with three (3) or more MPC10's installed in a single chassis with OSPF enabled and configured on the device. An Insufficient Resource Pool weakness allows an attacker to cause the device's Open Shortest Path First (OSPF) states to transition to Down, resulting in a Denial of Service (DoS) attack. This attack requires a relatively large number of specific Internet Mixed (IMIXed) types of genuine and valid IPv6 packets to be transferred by the attacker in a relatively short period of time, across three or more PFE's on the device at the same time. Continued receipt of the traffic sent by the attacker will continue to cause OSPF to remain in the Down starting state, or flap between other states and then again to Down, causing a persistent Denial of Service. This attack will affect all IPv4, and IPv6 traffic served by the OSPF routes once the OSPF states transition to Down. This issue affects: Juniper Networks Junos OS on MX480, MX960, MX2008, MX2010, MX2020: 18.1 versions prior to 18.1R2-S4, 18.1R3-S5; 18.1X75 version 18.1X75-D10 and later versions; 18.2 versions prior to 18.2R1-S5, 18.2R2-S3, 18.2R3; 18.2X75 versions prior to 18.2X75-D50; 18.3 versions prior to 18.3R1-S4, 18.3R2, 18.3R3; 18.4 versions prior to 18.4R1-S2, 18.4R2. | ||||
CVE-2019-0007 | 1 Juniper | 17 Junos, Mx10, Mx10003 and 14 more | 2024-11-21 | N/A |
The vMX Series software uses a predictable IP ID Sequence Number. This leaves the system as well as clients connecting through the device susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F5 on vMX Series. | ||||
CVE-2018-15504 | 2 Embedthis, Juniper | 134 Appweb, Goahead, Ex2200 and 131 more | 2024-11-21 | 7.5 High |
An issue was discovered in Embedthis GoAhead before 4.0.1 and Appweb before 7.0.2. The server mishandles some HTTP request fields associated with time, which results in a NULL pointer dereference, as demonstrated by If-Modified-Since or If-Unmodified-Since with a month greater than 11. | ||||
CVE-2018-0002 | 1 Juniper | 31 Junos, Mx10, Mx104 and 28 more | 2024-11-21 | N/A |
On SRX Series and MX Series devices with a Service PIC with any ALG enabled, a crafted TCP/IP response packet processed through the device results in memory corruption leading to a flowd daemon crash. Sustained crafted response packets lead to repeated crashes of the flowd daemon which results in an extended Denial of Service condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX series; 12.3X48 versions prior to 12.3X48-D35 on SRX series; 14.1 versions prior to 14.1R9 on MX series; 14.2 versions prior to 14.2R8 on MX series; 15.1X49 versions prior to 15.1X49-D60 on SRX series; 15.1 versions prior to 15.1R5-S8, 15.1F6-S9, 15.1R6-S4, 15.1R7 on MX series; 16.1 versions prior to 16.1R6 on MX series; 16.2 versions prior to 16.2R3 on MX series; 17.1 versions prior to 17.1R2-S4, 17.1R3 on MX series. No other Juniper Networks products or platforms are affected by this issue. | ||||
CVE-2017-10611 | 1 Juniper | 15 Ex2200, Ex3300, Junos and 12 more | 2024-11-21 | N/A |
If extended statistics are enabled via 'set chassis extended-statistics', when executing any operation that fetches interface statistics, including but not limited to SNMP GET requests, the pfem process or the FPC may crash and restart. Repeated crashes of PFE processing can result in an extended denial of service condition. This issue only affects the following platforms: (1) EX2200, EX3300, XRE200 (2) MX Series routers with MPC7E/8E/9E PFEs installed, and only if 'extended-statistics' are enabled under the [edit chassis] configuration. Affected releases are Juniper Networks Junos OS 14.1 prior to 14.1R8-S5, 14.1R9 on MX Series; 14.1X53 prior to 14.1X53-D46, 14.1X53-D50 on EX2200, EX3300, XRE200; 14.2 prior to 14.2R7-S9, 14.2R8 on MX Series; 15.1 prior to 15.1F5-S8, 15.1F6-S8, 15.1R5-S3, 15.1R6 on MX Series; 16.1 prior to 16.1R4-S5, 16.1R5, 16.1R6 on MX Series; 16.1X65 prior to 16.1X65-D45 on EX2200, EX3300, XRE200; 16.2 prior to 16.2R2-S1, 16.2R3 on MX Series; 17.1 prior to 17.1R2-S2, 17.1R3 on MX Series; 17.2 prior to 17.2R1-S3, 17.2R2 on MX Series; 17.2X75 prior to 17.2X75-D50 on MX Series; 17.3 prior to 17.3R1-S1, 17.3R2 on MX Series. No other Juniper Networks products or platforms are affected by this issue. | ||||
CVE-2014-9708 | 3 Embedthis, Juniper, Oracle | 134 Appweb, Ex2200, Ex2200-c and 131 more | 2024-11-21 | N/A |
Embedthis Appweb before 4.6.6 and 5.x before 5.2.1 allows remote attackers to cause a denial of service (NULL pointer dereference) via a Range header with an empty value, as demonstrated by "Range: x=,". | ||||
CVE-2014-6382 | 1 Juniper | 11 Junos, Mx10, Mx104 and 8 more | 2024-11-21 | N/A |
The Juniper MX Series routers with Junos 13.3R3 through 13.3Rx before 13.3R6, 14.1 before 14.1R4, 14.1X50 before 14.1X50-D70, and 14.2 before 14.2R2, when configured as a broadband edge (BBE) router, allows remote attackers to cause a denial of service (jpppd crash and restart) by sending a crafted PAP Authenticate-Request after the PPPoE Discovery and LCP phase are complete. |