Search Results (76 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-46284 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2025-01-14 7.5 High
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
CVE-2023-46283 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2025-01-14 7.5 High
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
CVE-2023-46282 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2025-01-14 7.1 High
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
CVE-2023-46281 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2025-01-14 7.1 High
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
CVE-2023-46096 1 Siemens 1 Simatic Pcs Neo 2025-01-08 6.5 Medium
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.
CVE-2023-46097 1 Siemens 1 Simatic Pcs Neo 2025-01-08 6.3 Medium
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.
CVE-2023-46098 1 Siemens 1 Simatic Pcs Neo 2025-01-08 8 High
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
CVE-2023-46099 1 Siemens 1 Simatic Pcs Neo 2025-01-08 5.4 Medium
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user.
CVE-2023-28829 1 Siemens 4 Simatic Net Pc Software, Simatic Pcs 7, Simatic Wincc and 1 more 2025-01-03 3.9 Low
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
CVE-2023-48364 1 Siemens 6 Openpcs 7, Simatic Batch, Simatic Pcs 7 and 3 more 2024-11-21 6.5 Medium
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
CVE-2023-48363 1 Siemens 6 Openpcs 7, Simatic Batch, Simatic Pcs 7 and 3 more 2024-11-21 6.5 Medium
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
CVE-2023-25910 1 Siemens 3 Simatic Pcs 7, Simatic S7-pm, Simatic Step 7 2024-11-21 10 Critical
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
CVE-2022-27194 1 Siemens 3 Simatic Pcs Neo, Sinetplan, Totally Integrated Automation Portal 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.
CVE-2021-41057 3 Microsoft, Siemens, Wibu 11 Windows, Pss Cape, Pss E and 8 more 2024-11-21 7.1 High
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
CVE-2021-40364 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 5.5 Medium
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
CVE-2021-40363 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 7.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
CVE-2021-40360 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 8.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
CVE-2021-40358 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 9.9 Critical
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
CVE-2021-3449 13 Checkpoint, Debian, Fedoraproject and 10 more 172 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 169 more 2024-11-21 5.9 Medium
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
CVE-2021-31894 1 Siemens 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more 2024-11-21 8.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.