CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: WCNCR00432661; Issue ID: MSV-3904. |
In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to remote (proximal/adjacent) escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00422323; Issue ID: MSV-3810. |
In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to remote (proximal/adjacent) escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00422399; Issue ID: MSV-3748. |
In wlan AP driver, there is a possible out of bounds write due to an integer overflow. This could lead to remote (proximal/adjacent) escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00418785; Issue ID: MSV-3515. |
In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to remote (proximal/adjacent) escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00415809; Issue ID: MSV-3405. |
Session Fixation vulnerability in Rolantis Information Technologies Agentis allows Session Hijacking.This issue affects Agentis: before 4.44. |
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. |
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution. |
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured. |
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.3), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.3). The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition. |
ZTE's ZXCDN product is affected by a Struts remote code execution (RCE) vulnerability. An unauthenticated attacker can remotely execute commands with non-root privileges. |
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
An low privileged remote attacker with an account for the Web-based management can change the system configuration to perform a command injection as root, resulting in a total loss of confidentiality, availability and integrity due to improper control of generation of code ('Code Injection'). |
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component. |
The web server of affected devices do not properly authenticate user request to the '/ClientArea/RuntimeInfoData.mwsl' endpoint. This could allow an unauthenticated remote attacker to gain knowledge about current actual and configured maximum cycle times as well as about configured maximum communication load. |
The web server of affected devices does not properly validate input that is used for a user redirection. This could allow an attacker to make the server redirect the legitimate user to an attacker-chosen URL. For a successful exploit, the legitimate user must actively click on an attacker-crafted link. |
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products support insecure cryptographic algorithms. An attacker could leverage these legacy algorithms to achieve a man-in-the-middle attack or impersonate communicating parties. |
In Eclipse ThreadX before version 6.4.3, an attacker can cause a denial of service (crash) by providing a pointer to a reserved or unmapped memory region. Vulnerable system calls had a check of pointers, but that check wasn't verifying whether the pointer is outside the module memory region. |
The websocket handler is vulnerable to a denial of service condition. An unauthenticated remote attacker can send a crafted websocket message to trigger the issue without affecting the core functionality. |