Filtered by vendor Omron Subscriptions
Total 90 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2015-0987 1 Omron 3 Cj2h Plc, Cj2m Plc, Cx-programmer 2024-08-06 N/A
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.
CVE-2018-18993 1 Omron 3 Cx-one, Cx-programmer, Cx-server 2024-08-05 7.8 High
Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.
CVE-2018-18989 1 Omron 3 Cx-one, Cx-programmer, Cx-server 2024-08-05 N/A
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-16207 1 Omron 1 Poweract Pro Master Agent 2024-08-05 N/A
PowerAct Pro Master Agent for Windows Version 5.13 and earlier allows authenticated attackers to bypass access restriction to alter or edit unauthorized files via unspecified vectors.
CVE-2018-6624 1 Omron 7 Ns10, Ns12, Ns15 and 4 more 2024-08-05 N/A
OMRON NS devices 1.1 through 1.3 allow remote attackers to bypass authentication via a direct request to the .html file for a specific screen, as demonstrated by monitor.html.
CVE-2019-18261 1 Omron 3 Plc Cj Firmware, Plc Cs Firmware, Plc Nj Firmware 2024-08-05 9.8 Critical
In Omron PLC CS series, all versions, Omron PLC CJ series, all versions, and Omron PLC NJ series, all versions, the software does not implement sufficient measures to prevent multiple failed authentication attempts within in a short time frame, making it more susceptible to brute force attacks.
CVE-2019-18251 2 Omron, Teamviewer 2 Cx-supervisor, Teamviewer 2024-08-05 8.8 High
In Omron CX-Supervisor, Versions 3.5 (12) and prior, Omron CX-Supervisor ships with Teamviewer Version 5.0.8703 QS. This version of Teamviewer is vulnerable to an obsolete function vulnerability requiring user interaction to exploit.
CVE-2019-18259 1 Omron 2 Plc Cj Firmware, Plc Cs Firmware 2024-08-05 9.8 Critical
In Omron PLC CJ series, all versions and Omron PLC CS series, all versions, an attacker could spoof arbitrary messages or execute commands.
CVE-2019-18269 1 Omron 2 Plc Cj Firmware, Plc Cs Firmware 2024-08-05 9.8 Critical
Omron’s CS and CJ series PLCs have an unrestricted externally accessible lock vulnerability.
CVE-2019-13533 1 Omron 2 Plc Cj Firmware, Plc Cs Firmware 2024-08-04 8.1 High
In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves.
CVE-2019-10971 1 Omron 1 Network Configurator For Devicenet Safety 2024-08-04 N/A
The application (Network Configurator for DeviceNet Safety 3.41 and prior) searches for resources by means of an untrusted search path that could execute a malicious .dll file not under the application's direct control and outside the intended directories.
CVE-2019-6556 1 Omron 2 Common Components, Cx-programmer 2024-08-04 N/A
When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2020-6986 1 Omron 4 Plc Cj1, Plc Cj1 Firmware, Plc Cj2 and 1 more 2024-08-04 7.5 High
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
CVE-2021-27413 1 Omron 2 Cx-one, Cx-server 2024-08-03 7.8 High
Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
CVE-2021-20836 1 Omron 1 Cx-supervisor 2024-08-03 6.5 Medium
Out-of-bounds read vulnerability in CX-Supervisor v4.0.0.13 and v4.0.0.16 allows an attacker with administrative privileges to cause information disclosure and/or arbitrary code execution by opening a specially crafted SCS project files.
CVE-2022-46282 1 Omron 1 Cx-drive 2024-08-03 7.8 High
Use after free vulnerability in CX-Drive V3.00 and earlier allows a local attacker to execute arbitrary code by having a user to open a specially crafted file,
CVE-2022-45790 1 Omron 92 Cj1g-cpu42p, Cj1g-cpu42p Firmware, Cj1g-cpu43p and 89 more 2024-08-03 8.6 High
The Omron FINS protocol has an authenticated feature to prevent access to memory regions. Authentication is susceptible to bruteforce attack, which may allow an adversary to gain access to protected memory. This access can allow overwrite of values including programmed logic.
CVE-2022-45792 1 Omron 1 Sysmac Studio 2024-08-03 7.8 High
Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.
CVE-2022-45793 1 Omron 1 Automation Software Sysmac Studio 2024-08-03 5.5 Medium
Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user.
CVE-2022-45794 1 Omron 82 Sysmac Cj1g-cpu42p, Sysmac Cj1g-cpu42p Firmware, Sysmac Cj1g-cpu43p and 79 more 2024-08-03 8.6 High
An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.