Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. |
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access. |
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter. |
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter. |
The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication. |
IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor. |
Philips MRI 1.5T and MRI 3T Version 5.x.x assigns an owner who is outside the intended control sphere to a resource. |
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.) |
Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution. |
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
|
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.
|
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct.
|
In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certificate enrollment service to
crash. It does not impact monitoring but prevents new devices from
enrolling.
|
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data via a read-only web
application.
|
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
|
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.
|
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges. |
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol. |
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client. |