Filtered by vendor Siemens Subscriptions
Total 1847 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-12736 1 Siemens 15 Ruggedcom, Ruggedcom Ros, Ruggedcom Rsl910 and 12 more 2024-09-17 N/A
A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices (All versions < ROS V5.0.1), RUGGEDCOM ROS for all other devices (All versions < ROS V4.3.4), SCALANCE XB-200/XC-200/XP-200/XR300-WG (All versions between V3.0 (including) and V3.0.2 (excluding)), SCALANCE XR-500/XM-400 (All versions between V6.1 (including) and V6.1.1 (excluding)). After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to writeto the device under certain conditions, potentially allowing users located in the adjacentnetwork of the targeted device to perform unauthorized administrative actions.
CVE-2011-4531 1 Siemens 1 Automation License Manager 2024-09-17 N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2012-3020 1 Siemens 2 Synco Ozw Web Server, Synco Ozw Web Server Firmware 2024-09-17 N/A
The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.
CVE-2018-11447 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2024-09-17 N/A
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2015-5374 1 Siemens 3 Siprotec 4, Siprotec Compact, Siprotec Firmware 2024-09-17 N/A
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.
CVE-2011-4532 1 Siemens 1 Automation License Manager 2024-09-17 N/A
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
CVE-2012-2598 1 Siemens 1 Wincc 2024-09-17 N/A
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
CVE-2011-4529 1 Siemens 1 Automation License Manager 2024-09-17 N/A
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
CVE-2012-2595 1 Siemens 1 Wincc 2024-09-17 N/A
Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.
CVE-2018-4834 1 Siemens 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more 2024-09-17 9.8 Critical
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.
CVE-2013-0659 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2024-09-17 N/A
The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185.
CVE-2013-0656 1 Siemens 2 Simatic Rf-manager, Simatic Rf-manager 2008 2024-09-17 N/A
Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.
CVE-2012-3037 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2024-09-17 N/A
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
CVE-2011-4509 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-09-17 N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
CVE-2019-8268 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2024-09-17 9.8 Critical
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
CVE-2019-13935 1 Siemens 1 Polarion 2024-09-17 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2022-2097 6 Debian, Fedoraproject, Netapp and 3 more 16 Debian Linux, Fedora, Active Iq Unified Manager and 13 more 2024-09-17 5.3 Medium
AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn't written. In the special case of "in place" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected. Fixed in OpenSSL 3.0.5 (Affected 3.0.0-3.0.4). Fixed in OpenSSL 1.1.1q (Affected 1.1.1-1.1.1p).
CVE-2018-5380 4 Canonical, Debian, Quagga and 1 more 5 Ubuntu Linux, Debian Linux, Quagga and 2 more 2024-09-17 N/A
The Quagga BGP daemon (bgpd) prior to version 1.2.3 can overrun internal BGP code-to-string conversion tables used for debug by 1 pointer value, based on input.
CVE-2018-4846 1 Siemens 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more 2024-09-17 N/A
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
CVE-2018-4851 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2024-09-17 N/A
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.