Filtered by vendor Tenda
Subscriptions
Total
870 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-45481 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. | ||||
CVE-2024-2485 | 1 Tenda | 1 Ac18 Firmware | 2024-08-02 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2023-42320 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. | ||||
CVE-2023-41553 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-08-02 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. | ||||
CVE-2023-41558 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. | ||||
CVE-2023-41561 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-08-02 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. | ||||
CVE-2023-41557 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac7 and 1 more | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | ||||
CVE-2023-41552 | 1 Tenda | 4 Ac7, Ac7 Firmware, Ac9 and 1 more | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. | ||||
CVE-2023-41563 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-08-02 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. | ||||
CVE-2023-41556 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. | ||||
CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | ||||
CVE-2023-41554 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. | ||||
CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. | ||||
CVE-2023-41560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. | ||||
CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-08-02 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | ||||
CVE-2023-40845 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks. | ||||
CVE-2023-40904 | 1 Tenda | 2 Ac10v4, Ac10v4 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. | ||||
CVE-2023-40840 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat." | ||||
CVE-2023-40846 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. | ||||
CVE-2023-40895 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. |