CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-32518 | 1 Schneider-electric | 1 Data Center Expert | 2024-08-03 | 8 High |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0) | ||||
CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-08-03 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32512 | 1 Schneider-electric | 1 Canbrass | 2024-08-03 | 5.3 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1) | ||||
CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-08-03 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-26507 | 2 Att, Schneider-electric | 9 Xmill, Ecostruxure Control Expert, Ecostruxure Process Expert and 6 more | 2024-08-03 | 9.8 Critical |
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer | ||||
CVE-2022-24323 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Ecostruxure Process Expert | 2024-08-03 | 5.3 Medium |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior) | ||||
CVE-2022-24318 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-08-03 | 7.5 High |
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
CVE-2022-24319 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-08-03 | 5.9 Medium |
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
CVE-2022-24310 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 9.8 Critical |
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24321 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-08-03 | 7.5 High |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
CVE-2022-24311 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 9.8 Critical |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24314 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 7.5 High |
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24322 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-08-03 | 5.3 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior) | ||||
CVE-2022-24315 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 7.5 High |
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24317 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 7.5 High |
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24313 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-08-03 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
CVE-2022-24320 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-08-03 | 5.9 Medium |
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
CVE-2022-24316 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 7.5 High |
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
CVE-2022-24312 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-08-03 | 9.8 Critical |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |