| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Import function in MintHCM RELEASE 3.0.8 allows an attacker to execute a cross-site scripting (XSS) payload in file-upload. |
| A heap buffer overflow vulnerability inside of BMP image processing was found at [core] module of ONLYOFFICE DocumentServer v4.0.0-9-v6.0.0. Using this vulnerability, an attacker is able to gain remote code executions on DocumentServer. |
| Command injection vulnerability in China Mobile An Lianbao WF-1 1.01 via the 'ip' parameter with a POST request to /api/ZRQos/set_online_client. |
| Cross site Scripting (XSS) vulnerability in MERCUSYS Mercury X18G 1.0.5 devices, via crafted values to the 'src_dport_start', 'src_dport_end', and 'dest_port' parameters. |
| Multiple stored cross site scripting (XSS) vulnerabilities in the "Update Profile" module of Online Doctor Appointment System 1.0 allows authenticated attackers to execute arbitrary web scripts or HTML via crafted payloads in the First Name, Last Name, and Address text fields. |
| Multiple stored cross site scripting (XSS) vulnerabilities in the "Register" module of House Rental and Property Listing 1.0 allows authenticated attackers to execute arbitrary web scripts or HTML via crafted payloads in all text fields except for Phone Number and Alternate Phone Number. |
| Taocms v2.5Beta5 was discovered to contain a cross-site scripting (XSS) vulnerability via the component Management column. |
| JetBrains TeamCity before 2020.2 was vulnerable to reflected XSS on several pages. |
| The USB vHub in the Teradici PCOIP Software Agent prior to version 21.07.0 would accept commands from any program, which may allow an attacker to elevate privileges by changing the flow of program execution within the vHub driver. |
| An out of bounds write in Teradici PCoIP soft client versions prior to version 20.10.1 could allow an attacker to remotely execute code. |
| It was discovered that the get_pid_info() function in data/apport did not properly parse the /proc/pid/status file from the kernel. |
| A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529) |
| A vulnerability has been identified in RWG1.M12 (All versions < V1.16.16), RWG1.M12D (All versions < V1.16.16), RWG1.M8 (All versions < V1.16.16). Sending specially crafted ARP packets to an affected device could cause a partial denial-of-service, preventing the device to operate normally. A restart is needed to restore normal operations. |
| A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608) |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. |
| A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time. |
| A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700) |
| Stored XSS injection vulnerabilities were discovered in the Avaya Aura Experience Portal Web management which could allow an authenticated user to potentially disclose sensitive information. Affected versions include 7.0 through 7.2.3 (without hotfix) and 8.0.0 (without hotfix). |
| Mobile application "Testes de Codigo" v11.3 and prior allows stored XSS by injecting a payload in the "feedback" message field causing it to be stored in the remote database and leading to its execution on client devices when loading the "feedback list", either by accessing the website directly or using the mobile application. |